1506-065-K-6-17
16
Five
-digit entry
codes will not
activate
relay 2
.
•
Be sure entry code is programmed into the keypad.
•
Enter five-digit code directly on keypad.
DO NOT
press
#
first.
•
Be sure entry code is less than divide number or reprogram divide number. (Section 2.11)
SECTION 4 - MAINTENANCE
4.1 Troubleshooting
•
Have a good VOM meter to use when checking voltages and continuity.
•
Check power wiring wire size and distance. Improper wire size and too long wire run distances can cause problems.
•
Check the power transformer.
Keypad emits a long
tone and cancels
programming.
System is dead.
Symptom
Possible Solution(s)
•
Wrong master code entered. Start over.
•
Waiting too long between pushing buttons. Enter information quicker.
•
Keypad may not be plugged in correctly. Unplug and reconnect.
Cannot get into
programming mode.
•
Waiting too long between pushing buttons while programming.
•
Forgetting to press
*
first when programming.
•
Memory is filled. Delete some entry codes or erase entire memory.
Relay(s) lock on for
long periods of time.
•
Excessive voltage-drop on power wires. Check transformer and wire size.
•
Transformer
has
too low
VA rating.
•
Relay hold feature may be activated. Reprogram hold boundaries. (Section 2.12)
•
Relay strike time may be programmed too long. Reprogram. (Section 2.2)
Request to exit input
will not operate relay.
•
Check wiring connected to terminals 1 and 12.
Four
-digit entry
codes will not
activate
relay 1
.
•
Be sure entry code is programmed into the keypad.
•
Press
#
first, then enter four-digit number.
•
Code may be time zone restricted. Reprogram time zone or disable time zone input. (Sec 2.13/2.14)
•
Be sure entry code is less than divide number or reprogram divide number. (Section 2.7)
Five
-digit entry
codes will not
activate
relay 1
.
•
Be sure entry code is programmed into the keypad.
•
Enter five-digit code directly on keypad.
DO NOT
press
#
first.
•
Be sure entry code is less than divide number or reprogram divide number. (Section 2.11)
•
Check for power at terminals 13 and 14.
•
Keypad may not be plugged in correctly. Unplug and reconnect.
•
X strikes feature may be activated. Wait 3 minutes and try again. (Section 2.3)
Four
-digit entry
codes will not
activate
relay 2
.
•
Be sure entry code is programmed into the keypad.
•
Press # first, then enter four-digit number.
•
Code may be time zone restricted. Reprogram time zone or disable time zone input. (Sec 2.13/2.14)
•
Be sure entry code is greater than divide number or reprogram divide number. (Section 2.7)
Summary of Contents for 1506-086