2.1 Re-Programming the Master Code

2.2 Relay Strike Time

Step 1.

 Open the cabinet and locate the 

Master Code switch on the circuit board. 
Turn switch 

ON

Step 2.

 Enter a four-digit master code using the keypad, then press “

*

” (A short beep will be heard).

Step 3.

 Turn 

OFF

 the Master Code switch and close cabinet.

          Write down master code and keep it in a secure place.

?

?

?

?

any four numbers

Then press 

“BEEP”

Same keystrokes as written in this manual:   

[ _ _ _ _ 

*

 (beep)]

Actual keystrokes used on keypad:

SECTION 2 - PROGRAMMING

Before You Start Programming: IMPORTANT!

 Make sure the 1504/1506 has power and we suggest that you become familiar 

with programming instructions before beginning any programming.
Keep a record of the programmed codes by completing the tables on pages 24 and 25.

The Master Code has been pre-programmed at the factory to 9999

. This programming sequence re-programs the 

MASTER 

CODE 

if desired. The master code is the four-digit number required to gain access to the system memory. You 

MUST

 know the 

master code before programming 

ANY

 features.

 Important Note:

  After re-programming the master code, write it down and keep it in a safe place. 

There is no way of retrieving 

the master code after it has been programmed in.

 If you forget it, you will have to program in a new one but all other previously 

programmed information will remain intact.

The relay strike time sets the amount of time that the relay(s) will be activated when a valid entry code is entered on the keypad. 
The unit has two relays, both of which can be programmed with individual strike times. Setting the strike time to “

00

” will 

activate the relay for ½ second. It can be set to a max of 99 seconds. Two digits 

MUST

 be entered in the fields. 

Factory setting is 01 (1 Second).

1.

 Press 

*

 0 3 and enter the MASTER CODE. 

[

*

 

0 3 _ _ _ _ (beep)]

2.

 Enter the two-digit strike time for Relay 1 (00-99), then press 

*

[ _ _ 

*

(beep)]

3.

 Enter the two-digit strike time for Relay 2 (00-99), then press 

*

[ _ _ 

*

(beep)]

4.

 Press 0 # TOGETHER to end. 

[0 # (beeeeeep)]

2.3 X Strikes for Invalid Entry Code Attempts

This keypad has a 

3-minute lockout feature

 that is activated when “X” number of 

INVALID

 entry codes are entered on the 

keypad. The “X” strikes can be programmed from 

1

 to 

9

 invalid attempts before the lockout feature is activated.

Factory setting is 3 (3 Attempts).

1.

 Press 

*

 0 4 and enter the MASTER CODE. 

[

*

 

0 4 _ _ _ _ (beep)]

2.

 Enter the single-digit invalid attempts before the lockout feature is activated (1-9), then press 

*

[ _ 

*

(beep)]

3.

 Press 0 # TOGETHER to end. 

[0 # (beeeeeep)]

ON

OFF

ON

OFF

Note:

 After you turn ON the master code switch, the system will sound a short 

tone after 30 seconds if the master code is not entered. This tone will continue 
every 30 seconds until a new master code is entered, or until the switch is 
turned off.

Summary of Contents for 1506-086

Page 1: ...Stand Alone Digital Keypad Entry Devices Date Installed Installer Company Name Phone Number Leave Manual with Owner Circuit Board Serial Number and Revision Letter Model Number 1504 1504 1504 1506 150...

Page 2: ......

Page 3: ...ALL Four digit Entry Codes 2 7 Four digit Entry Code Divide Number 2 8 Programming Five digit Entry Codes 2 9 Erase a Five digit Entry Code 2 10 Erase ALL Five digit Entry Codes 2 11 Five digit Entry...

Page 4: ...e rough in box Flush Box Flush Box Flush Box Push Button Push Button To Call To Call Push Button Push Button To Call To Call 1504 Surface Mount Dimensions P N 1504 086 10 5 25 6 125 2 5 2 5 1 125 Dia...

Page 5: ...Box Flush Box Side Views Bottom Views Front Views Bolt holes 4 to secure flush box inside rough in box Flush Box Flush Box 1506 Surface Mount Dimensions P N 1506 086 Mounting Note Can be mounted on a...

Page 6: ...ng diagrams in this manual Never mount this device to a moving gate or gate panel or next to a gate that causes vibration to the fence such as a spring loaded pedestrian gate Continuous vibration from...

Page 7: ...is not subject to continuous vibration from closing doors or gates Use existing 4 holes in surface mount cabinet box to bolt on a DoorKing mounting post Use the hardware that is supplied with the moun...

Page 8: ...te 12 24 VDC may also be used to power the 1504 1506 Note A low voltage power surge suppressor P N 1878 010 is recommended Power for electric strike or maglock is NOT provided by the 1504 1506 Use sep...

Page 9: ...1504 Aiphone Intercom Station Connections Intercom Station 1504 AIPhone LEM Series 2 Wire System 3 Wire System E 1 Push to Call Button Speaker Blue Blue Red Red Capacitor 47uF 1504 Push to Call Butto...

Page 10: ...1 4 M A S T E R C O D E O N 1 5 0 6 0 1 0 1 2 3 4 5 6 7 8 1 5 9 9 0 1 0 1 2 3 4 5 6 7 8 1 5 9 7 0 1 0 1599 Secondary Keypad Board 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1597 010 8 Conductor...

Page 11: ...m in a new one but all other previously programmed information will remain intact The relay strike time sets the amount of time that the relay s will be activated when a valid entry code is entered on...

Page 12: ...HAN the divide number will activate Relay 2 If NO divide number is programmed enter in step 2 then Relay 2 acts as an alarm by pass relay activating 1 second PRIOR to Relay 1 and deactivating 1 second...

Page 13: ...s must be programmed to operate in the same mode If a divide number is programmed for the five digit codes then a divide number MUST also be programmed for the four digit entry codes see section 2 7 F...

Page 14: ...R and UPPER boundaries for time ZONE 1 establishes a set of four digit entry codes that will be denied access if the time zone 1 input terminal 4 is activated Note This time zone does not affect the f...

Page 15: ...can be programmed to operate either Relay 1 or Relay 2 When a five digit code is entered on the keypad the system checks its memory to see if the code is stored If the five digit entry code is not sto...

Page 16: ...ate a relay that is latched simply re enter the number that was used to activate the relay See sample charts below Five digit entry codes are NOT affected by hold boundaries Relay 1 Relay 1 momentaril...

Page 17: ...ime zone restricted Entry codes 3001 thru 3999 are not time zone restricted Entry codes 5001 and higher are not time zone restricted Time Zone 1 Entry codes 2000 thru 3000 are restricted by Time ZONE...

Page 18: ...VA rating Relay hold feature may be activated Reprogram hold boundaries Section 2 12 Relay strike time may be programmed too long Reprogram Section 2 2 Request to exit input will not operate relay Ch...

Page 19: ...ec Master Code section 2 1 Factory 9999 1st Digit 2nd Digit 3rd Digit 4th Digit Four digit Hold Boundaries section 2 12 Lower Upper Time ZONE 1 Boundaries section 2 13 Lower Upper Time ZONE 2 Boundari...

Page 20: ...1506 065 K 6 17 18 NAME Four Digit Entry Code Make additional copies of this table as needed NAME Four Digit Entry Code Resident Four Digit Entry Codes...

Page 21: ...1506 065 K 6 17 19 NAME Four Digit Entry Code Make additional copies of this table as needed NAME Four Digit Entry Code Resident Four Digit Entry Codes...

Page 22: ...310 645 0023 Fax 310 641 1586 Installation Owner s Manual Models 1504 1506 Models 1504 1506 Models 1504 1506 Use this manual for circuit board 1506 010 Revision G or higher Programmable Stand Alone Di...

Reviews: