background image

1506-065-K-6-17

14

3.5 Hold Feature Operation

The relay hold feature allows a set of 

four-digit entry codes

 to latch (or hold) a relay indefinitely. Any 

four-digit entry code

 that 

falls numerically within the hold boundaries will cause relay 1 to activate indefinitely if no four-digit divide number is 
programmed.

If a four-digit divide number is programmed, and the divide number is 

less than

 the lower hold boundary, then the four-digit 

codes within the hold boundary will activate relay 2.

If a four-digit divide number is programmed, and the divide number is 

greater than

 the upper hold boundary, then the four-digit 

codes within the hold boundary will activate relay 1.

If a four-digit divide number is programmed, and it falls between the hold boundaries, then four-digit entry codes 

equal to

 or 

less than

 the divide number, but 

greater than

 the lower hold boundary, will activate relay 1 indefinitely.

Four-digit entry codes that are 

greater than

 the divide number, but 

less than

 the upper hold boundary, will activate relay 2 

indefinitely. To 

deactivate

 a relay that is 

latched

, simply re-enter the number that was used to activate the relay. See sample 

charts below.

Five-digit entry codes

 are 

NOT

 affected by hold boundaries.

Relay 1

Relay 1 momentarily
activates with entry 
code 2000 or lower.

Relay 2

Relay 2 momentarily
activates with entry 
codes 2001 thru 2009.

Relay 2 latches when
entry codes 2010 thru 
2015 are entered on 
the keypad.

Relay 2 momentarily
activates with entry 
codes 2016 and 
higher.

Divide Number 2000

Lower Hold

Boundar

y 2010

Upper Hold

Boundar

y 2015

Example 1

Relay 1

Relay 1 momentarily
activates with entry 
code 2009 or lower.

Relay 2

Relay 1 latches when
entry codes 2010 thru 
2015 are entered on 
the keypad.

Relay 1 momentarily
activates with entry 
codes 2016 thru 
2025.

Relay 2 momentarily
activates with entry 
code 2026 or
higher.

Divide Number 2025

Upper Hold

Boundar

y 2015

Lower Hold

Boundar

y 2010

Example 2

Relay 1

Relay 1 momentarily
activates with entry 
code 2009 or lower.

Relay 2

Relay 1 latches when
entry codes 2010 thru 
2012 are entered on 
the keypad.

Relay 2 latches when
entry codes 2013 thru 
2015 are entered on
keypad.

Relay 2 momentarily
activates with entry 
code 2016 and
higher.

Divide Number 2012

Upper Hold

Boundar

y 2015

Lower Hold

Boundar

y 2010

Example 3

Summary of Contents for 1506-086

Page 1: ...Stand Alone Digital Keypad Entry Devices Date Installed Installer Company Name Phone Number Leave Manual with Owner Circuit Board Serial Number and Revision Letter Model Number 1504 1504 1504 1506 150...

Page 2: ......

Page 3: ...ALL Four digit Entry Codes 2 7 Four digit Entry Code Divide Number 2 8 Programming Five digit Entry Codes 2 9 Erase a Five digit Entry Code 2 10 Erase ALL Five digit Entry Codes 2 11 Five digit Entry...

Page 4: ...e rough in box Flush Box Flush Box Flush Box Push Button Push Button To Call To Call Push Button Push Button To Call To Call 1504 Surface Mount Dimensions P N 1504 086 10 5 25 6 125 2 5 2 5 1 125 Dia...

Page 5: ...Box Flush Box Side Views Bottom Views Front Views Bolt holes 4 to secure flush box inside rough in box Flush Box Flush Box 1506 Surface Mount Dimensions P N 1506 086 Mounting Note Can be mounted on a...

Page 6: ...ng diagrams in this manual Never mount this device to a moving gate or gate panel or next to a gate that causes vibration to the fence such as a spring loaded pedestrian gate Continuous vibration from...

Page 7: ...is not subject to continuous vibration from closing doors or gates Use existing 4 holes in surface mount cabinet box to bolt on a DoorKing mounting post Use the hardware that is supplied with the moun...

Page 8: ...te 12 24 VDC may also be used to power the 1504 1506 Note A low voltage power surge suppressor P N 1878 010 is recommended Power for electric strike or maglock is NOT provided by the 1504 1506 Use sep...

Page 9: ...1504 Aiphone Intercom Station Connections Intercom Station 1504 AIPhone LEM Series 2 Wire System 3 Wire System E 1 Push to Call Button Speaker Blue Blue Red Red Capacitor 47uF 1504 Push to Call Butto...

Page 10: ...1 4 M A S T E R C O D E O N 1 5 0 6 0 1 0 1 2 3 4 5 6 7 8 1 5 9 9 0 1 0 1 2 3 4 5 6 7 8 1 5 9 7 0 1 0 1599 Secondary Keypad Board 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1597 010 8 Conductor...

Page 11: ...m in a new one but all other previously programmed information will remain intact The relay strike time sets the amount of time that the relay s will be activated when a valid entry code is entered on...

Page 12: ...HAN the divide number will activate Relay 2 If NO divide number is programmed enter in step 2 then Relay 2 acts as an alarm by pass relay activating 1 second PRIOR to Relay 1 and deactivating 1 second...

Page 13: ...s must be programmed to operate in the same mode If a divide number is programmed for the five digit codes then a divide number MUST also be programmed for the four digit entry codes see section 2 7 F...

Page 14: ...R and UPPER boundaries for time ZONE 1 establishes a set of four digit entry codes that will be denied access if the time zone 1 input terminal 4 is activated Note This time zone does not affect the f...

Page 15: ...can be programmed to operate either Relay 1 or Relay 2 When a five digit code is entered on the keypad the system checks its memory to see if the code is stored If the five digit entry code is not sto...

Page 16: ...ate a relay that is latched simply re enter the number that was used to activate the relay See sample charts below Five digit entry codes are NOT affected by hold boundaries Relay 1 Relay 1 momentaril...

Page 17: ...ime zone restricted Entry codes 3001 thru 3999 are not time zone restricted Entry codes 5001 and higher are not time zone restricted Time Zone 1 Entry codes 2000 thru 3000 are restricted by Time ZONE...

Page 18: ...VA rating Relay hold feature may be activated Reprogram hold boundaries Section 2 12 Relay strike time may be programmed too long Reprogram Section 2 2 Request to exit input will not operate relay Ch...

Page 19: ...ec Master Code section 2 1 Factory 9999 1st Digit 2nd Digit 3rd Digit 4th Digit Four digit Hold Boundaries section 2 12 Lower Upper Time ZONE 1 Boundaries section 2 13 Lower Upper Time ZONE 2 Boundari...

Page 20: ...1506 065 K 6 17 18 NAME Four Digit Entry Code Make additional copies of this table as needed NAME Four Digit Entry Code Resident Four Digit Entry Codes...

Page 21: ...1506 065 K 6 17 19 NAME Four Digit Entry Code Make additional copies of this table as needed NAME Four Digit Entry Code Resident Four Digit Entry Codes...

Page 22: ...310 645 0023 Fax 310 641 1586 Installation Owner s Manual Models 1504 1506 Models 1504 1506 Models 1504 1506 Use this manual for circuit board 1506 010 Revision G or higher Programmable Stand Alone Di...

Reviews: