OPERATING GUIDE for your

 

GEM-DXRP1 KEYPAD 

© NAPCO 2006 

OI322  6/06 

SYSTEM READY 
10/01/06   12:09 AM 

Summary of Contents for Gemini GEM-DXRP1

Page 1: ...1 OPERATING GUIDE for your GEM DXRP1 KEYPAD NAPCO 2006 OI322 6 06 SYSTEM READY 10 01 06 12 09 AM...

Page 2: ...of readiness by testing it at least once a week in both the ac battery and battery only modes ask your alarm professional how to make these tests INTRODUCTION IMPORTANT TEST YOUR SYSTEM WEEKLY Test yo...

Page 3: ...ELL PHONE STYLE 24 SETTING THE DATE AND TIME 26 KEYPAD MESSAGES 27 GLOSSARY 30 SYSTEM TROUBLE ERROR CODES 33 TROUBLESHOOTING 38 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS J FOR SERVICE CALL _______...

Page 4: ...4 KEYPAD CONTROLS INDICATORS 1 2 3 4 5 6 7 12 9 10 11 8...

Page 5: ...ystem troubles displays etc See text 2 Resets residential smoke detectors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ON OFF Button Entry key Causes the entered code or selected function...

Page 6: ...ing in 10 second steps Note If you enter a wrong code the keypad will display INVALID ENTRY TRY AGAIN 3 Leave the premises Leave through the exit door before exit time expires Priority Arming If you a...

Page 7: ...arm disarm a different area 1 Press the numerical key representing the other area number 2 Press Gfollowed by J The keypad will now provide status and control of that area 3 Enter your User Code foll...

Page 8: ...to automatically adjust the interior protection accordingly If you arm the system and remain in the house all Interior Zones are automatically bypassed The keypad will display BYPASSED indicating tha...

Page 9: ...it on your system GEM P3200 GEM P9600 V11D or less GEM P1632 V8G or less Press D to activate Easy Exit on your system GEM P3200 GEM P9600 V20 or greater GEM P816 P1632 V9A or greater Emergency Buttons...

Page 10: ...stem is disarmed the window will continue to display ALARM followed by the zone s violated 2 To reset the display note the zones violated then press C Ambush Optional Your Ambush Code Type is TYPE 1 P...

Page 11: ...a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down smoke cleared from detector etc pressing C again will reset the keypad w...

Page 12: ...th all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not sto...

Page 13: ...13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Page 14: ...es because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen...

Page 15: ...s detected for longer than one minute Display Zone Faults Displays the zone number of zones that are not secured Press the NEXT and PRIOR Buttons as displayed on screen to scroll faulted zones require...

Page 16: ...n the Fire Zone s Use NEXT E and PRIOR F to scroll zones required for GEM P3200 9600 panels GEM P816 1632 1664 panels will auto scroll Activate Chime The Chime Mode will sound a tone at the keypad whe...

Page 17: ...the Function Menu scroll to RESET SENSOR MSG and press D If you cannot correct the problem call for service Note This function available with GEM P9600 and GEM P3200 control panels only Start Exit Ti...

Page 18: ...o 4 hours To Delay Arm the system With the function TO ARM IN 1 4 HRS displayed in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by J At the end of this 1 4 hour Delay Ar...

Page 19: ...to the next group or PRIOR F to scroll back to the previous group Press C when done Note This function available with GEM P9600 and GEM P3200 control panels only Relay Group 01 _______________________...

Page 20: ...to 45 sec onds at your option by consulting with your installer Regular Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report...

Page 21: ...central station acknowledges receipt ringback exit delay will start If ringback is not heard within about 30 seconds a communication problem may exist call for service Function 11 Start Exit Time may...

Page 22: ...peat Steps 1 through 3 for each User Code to be programmed Erasing a User Code 1 Enter the digits of the user number to be erased followed by AA 2 Press G0 to erase each digit of the User Code and the...

Page 23: ...e code Note Duplicate Codes are not allowed therefore a duplicate Code entered in the LCD Window will erase when D is pressed Press C to exit the Program Mode Notes If the system contains more than on...

Page 24: ...he next zone or to any other zone Move the cursor to the displayed zone number i e 01 using A and B Change the zone number using keys 0 through 9 Enter two digits for the zone number after entering th...

Page 25: ...NO5 5 mno5 6 PQR6 6 pqr6 7 STU7 7 stu7 8 VWX8 8 vwx8 9 YZ90 9 yz90 0 SPACE 0 Reserved CELL PHONE STYLE ENTRY 1 ABC1 2 DEF2 3 GHI3 4 JKL4 7 STU7 8 VWX8 9 YZ90 6 PQR6 5 MNO5 0 Use A and B buttons to mov...

Page 26: ...00 enter 07 29 00 2 Press D to save the Date Programming the Time After entering in the Date press NEXT E for the Time Entry screen 1 At the Enter Time screen simply punch in the correct time using th...

Page 27: ...in seconds If displayed S indicates Service Code active I indicates arming with Instant protection Entry delay in progress XXX denotes entry time remaining in seconds System armed With the GEM P3200 9...

Page 28: ...ress C to silence sounder Evacuate premises or correct cause of alarm For partitioned systems only Code not valid for area Wrong code entered or Easy Bypass function not enabled In Global Arming Mode...

Page 29: ...receives an acknowledgment from the central station of the cancellation of the alarm signal Indicates problem s detected on system See examples below and SYSTEM TROUBLE ERROR CODES for a complete list...

Page 30: ...by its own keypad or by a keypad of a different Area through Managers Mode Arming Disarming Turning the system on off by entering your code at the keypad then pressing J Battery Backup power source in...

Page 31: ...larm This option is programmable by zone for the same duration as that programmed for Abort Delay see Abort Delay Report A transmission to a central station notifying of a change in the status of the...

Page 32: ...rior devices Entry delay only occurs if re entry takes place through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits within the premises us...

Page 33: ...System Trouble Condition Action E01 00 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker oth...

Page 34: ...equired for the GEM PIR and GEM GB The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warn...

Page 35: ...e Fail ure NN Relay Board Number Call installing company for service E15 NN RF Transmitter Tamper Wireless Transmitter Tamper Cover removed NN Transmitter Number Call installing company for service E1...

Page 36: ...le to detect activity in the area clear any obstacles which may be blocking the sensor from detecting activity Press C to clear the display and then use the Function Menu to Reset Sensor Watch Failure...

Page 37: ...Fire zone indicated Call installing company for service GEM P1632 GEM P816 and GEM P1664 panels only E51 00 Bell Siren Trouble There is a problem with the Bell or Siren Call installing company for se...

Page 38: ...the scrolling error codes which represent the trouble Press C and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 33 The Fire Alarm is sounding and...

Page 39: ...39 NOTES...

Page 40: ...any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system ma...