14
OPERATOR PROGRAMMING
NOTE:
Door closing is possible only when the «Automatic door closing» function is activated. When the door is closing, a
controlling command reverses the door to open again.
3. Prohibition of control commands for closing
Press «+»
«3» will light, press «Р»
Pressing «+» or «-» choose the function value: «Y» – on, «n» – off, (factory
setting – «n»)
Press «P» to save the settings
4. Type of safety device (photocells)
Press «+»
«4» will light, press «Р»
Pressing «+» or «-» choose the function value: «0» – external; «1» – built-in
(factory setting – «0»)
Press «P» to save the settings
5. Door opening height during ventilation
Press «+»
«5» will light, press «Р»
Pressing «+» or «-» choose the function value: «0» – 1000 mm; «1» – 200 mm
(factory setting – «0»)
Press «P» to save the settings
To control the «partial opening» function, it is necessary to select the number of the remote control button in the fourth menu
item (see section 6.3), which will subsequently activate this function. When you press the selected button on the remote control,
the door will open to the set position (see section 6.4, p. 5).
NOTE:
The selected button have to be saved in the receiver memory.
6. Force adjustment
Press «+»
«6» will light, press «Р»
Pressing «+» or «-» choose the function value: «1» – min. force, «6» – max. force (by
default – «3» )
Press «P» to save the settings
2. Absolute cycle counter
Press «+»
«2» will light, press «Р»
The first digit is displaied
The second digit is displaied
After you enter the menu item «2», 4 digits will be displayed in turn: the first digit — tens of thousands, the second digit —
thousands, the third digit — hundreds and the fourth digit — tens.
For example: the first digit — «0», the second digit — «1», the third digit — «3» and the fourth digit — «9». Total number of
cycles – 1 390.