12
OPERATOR PROGRAMMING
4. Ventilation (Partial opening)
Record remote button to control the partial opening of the door.
Pressing «+» and «-», set the value of the function «Y». Confirm your selection by pressing the «P» button.
After pressing the «P» button, the operator automatically switches to the recording mode of the control button.
NOTE:
In the absence of control commands, the program exits transmitter recording mode automatically in 20 sec. Setting of
the door lifting height see Section 6.5, p. 5.
Press «+»
«4» will light, press «Р»
Pressing «+» or «-» choose the function value: «Y» — on,
«n» — off, (factory setting — «n»)
5. Safety devices
6. Reverse of the carriage when the door is closed
Reverse of the carriage reduces the load on the chain allowing you to effortlessly unhook the door (to switch to the manual
mode).
Press «+»
«6» will light, press «Р»
Pressing «+» or «-» choose the function value: «0» — off,
«1» — small reverse, «2» — medium reverse, «3» — large
reverse
Press «P» to save the settings
NOTE:
Activate this function if you use safety devices.
7. Automatic door closing
P
+
-
P
+
-
Нажмите «P»
P
+
-
Нажмите «+» —
загорится «7»
Press «+», «7» will light
Press «Р»
Pressing «+» or «-» choose the function value: «0» — off, «1» — 30 sec
pause, «2» — 60 sec pause, ... «8» — 240 sec pause
8. Reset to factory settings
P
+
-
Press «+»
«8» will light, press «Р»
The display shows «r»
Press and hold button «P» for ten seconds. The
display will stop flashing «r» and the Board will reboot,
you will hear a short beep.
When the parameters are reset to the factory settings, the range of door movement, as well as the remotes recorded in
memory are not reset.
Press «+»
«5» will light, press «Р»
Pressing «+» or «-» choose the function value: «Y» — on, «n» — off,
(factory setting — «n»)
Press «P» to save the settings
On the remote transmitter, select the button you want to control the
operator with and press it twice.
Press «P» to save the settings