Connection Diagram Examples 
 

Common power supply for magnetic lock (Fail open – power to lock) 

 

 

Common power supply for lock release (Fail secure – power to unlock)

 

 

 

Common power supply for auto gate controller (using Normally Open contact)

 

 

 
Comments: 

Relay 2 can be used to operate a doorbell if there is no need to operate a second door. The wiring 

to connect the doorbell is via NO2 and COM2. Press 

#

, the SK401-E will send out a switching signal to the 

doorbell, as long as you press the” 

#

”, the doorbell will operate, it will stop when you release the ” 

#

” 

Summary of Contents for SK401-E

Page 1: ...SK401 E External Stand Alone Keypad Proximity Card Reader User Manual...

Page 2: ...he SK401 E has many extra features including block enrollment anti tamper alarm backlit keypad buttons These features make the SK401 E an ideal choice for door access not only for small shops and dome...

Page 3: ...M 125KHz Industry Standard Proximity Card 20mm 35mm Wiring Connections Electric Lock Exit Button DOTL External Alarm Door Bell Relay Adjustable Relay Output Time Adjustable Alarm Output Time Lock Outp...

Page 4: ...28V DC 12 18V AC Regulated Power Input Black AC DC 12 28V DC 12 18V AC Regulated Power Input Grey Black GND Negative Pole Blue NO1 Normally Open Relay 1 output White COM1 Common Connection for Relay...

Page 5: ...er supply for auto gate controller using Normally Open contact Comments Relay 2 can be used to operate a doorbell if there is no need to operate a second door The wiring to connect the doorbell is via...

Page 6: ...Add Card and a Delete Card to allow rapid card enrollment They are for Relay 1 only Anti Tamper Alarm The SK401 E uses an LDR light Dependent Resistor as an anti tamper alarm If the keypad facia is re...

Page 7: ...the Master PIN must be entered Note When adding users if the card fob or Pin user has been enrolled already you cannot add it again on the same relay or the device will give a bleep as an error It is...

Page 8: ...ntity is between 1 1000 To delete Card users by cards Note Users can be deleted continuously without exiting programming mode 3 Read Card The device can automatically identify the card of relay 1 or r...

Page 9: ...hat this is done outside programming mode so the user can undertake this themselves ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 3 Read Card or 3 User ID To set...

Page 10: ...numbers in a 10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes depending on the option selected below Normal status No keypad lockout or alarm 7...

Page 11: ...OTE This is also useful if the original Master Add and Delete Cards have been lost 1 Power down the SK401 E 2 Press the Star button and hold at the same time power up the keypad 3 Release the button u...

Page 12: ...Code 0 New Master Code Repeat New Master Code code 4 6 digits Add Card User 1 Read Card for relay 1 2 Read Card for relay 2 Add PIN User 1 User ID 1 1000 PIN for relay 1 1 User ID 1001 1100 PIN for re...