background image

Door, Alarm, Acoustic Signal,

 

Door Bell Settings 

Door Open Detection 

 

Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic 
contact of the lock, if the door is opened normally, but not closed after 1 minute, the internal buzzer will bleep 
automatically to remind people to close the door and continue for 1 minute before switching off automatically 

 
Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the 
lock, if the door is forced open, the internal buzzer and alarm output will both operate

 

To disable door open detection 

  6      0      #

 

(Default)

 

To enable door open detection 

  6      1      #

 

It is optional to connect the D_IN line to LOCK1 or LOCK 2 

Keypad Lockout & Alarm Output options

. If there are 10 invalid cards or 10 incorrect PIN numbers in a 

10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes, 
depending on the option selected below

 

Normal status: No keypad lockout 
or alarm   

  7      0      # 

(Default) 

Keypad Lockout 

  7      1      # 

Alarm Output 

  7      2      # 

Alarm output time

 

To set the alarm output time   

  8      1-3      #

 

(Default is 1 minute) 

(1-3 minutes available)

 

Acoustic Signal   

The acoustic signal can be set on or off. When on, the keypad will bleep when the key buttons are pressed, 
when off, the keypad will be in silent   

Normal status: On   

  8      6      # 

(Default) 

Acoustic signal Off 

  8      7      # 

Change Relay 2 to Door Bell 

(When there is no need to operate a second door, relay 2 can be set to operate as a door bell. The wiring is 
connecting the door bell to COM2 and NO2. Press #, and the keypad will send the signal to the door bell   

Relay 2 

  8      8      #   

(Default) 

Door bell 

  8      9      #   

To remove The Alarm

 

To reset the Door Forced Open 
warning 

Read valid card or Master Code # 

To reset the Door Open Too Long 
warning 

Close the door 

or    Read valid card or Master Code #

 

 

Summary of Contents for SK401-E

Page 1: ...SK401 E External Stand Alone Keypad Proximity Card Reader User Manual...

Page 2: ...he SK401 E has many extra features including block enrollment anti tamper alarm backlit keypad buttons These features make the SK401 E an ideal choice for door access not only for small shops and dome...

Page 3: ...M 125KHz Industry Standard Proximity Card 20mm 35mm Wiring Connections Electric Lock Exit Button DOTL External Alarm Door Bell Relay Adjustable Relay Output Time Adjustable Alarm Output Time Lock Outp...

Page 4: ...28V DC 12 18V AC Regulated Power Input Black AC DC 12 28V DC 12 18V AC Regulated Power Input Grey Black GND Negative Pole Blue NO1 Normally Open Relay 1 output White COM1 Common Connection for Relay...

Page 5: ...er supply for auto gate controller using Normally Open contact Comments Relay 2 can be used to operate a doorbell if there is no need to operate a second door The wiring to connect the doorbell is via...

Page 6: ...Add Card and a Delete Card to allow rapid card enrollment They are for Relay 1 only Anti Tamper Alarm The SK401 E uses an LDR light Dependent Resistor as an anti tamper alarm If the keypad facia is re...

Page 7: ...the Master PIN must be entered Note When adding users if the card fob or Pin user has been enrolled already you cannot add it again on the same relay or the device will give a bleep as an error It is...

Page 8: ...ntity is between 1 1000 To delete Card users by cards Note Users can be deleted continuously without exiting programming mode 3 Read Card The device can automatically identify the card of relay 1 or r...

Page 9: ...hat this is done outside programming mode so the user can undertake this themselves ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 3 Read Card or 3 User ID To set...

Page 10: ...numbers in a 10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes depending on the option selected below Normal status No keypad lockout or alarm 7...

Page 11: ...OTE This is also useful if the original Master Add and Delete Cards have been lost 1 Power down the SK401 E 2 Press the Star button and hold at the same time power up the keypad 3 Release the button u...

Page 12: ...Code 0 New Master Code Repeat New Master Code code 4 6 digits Add Card User 1 Read Card for relay 1 2 Read Card for relay 2 Add PIN User 1 User ID 1 1000 PIN for relay 1 1 User ID 1001 1100 PIN for re...

Reviews: