39
Laundry(dry)
L/S valve
Remarks
Small (0 ~ 2 KG)
66 or less
Middle (2KG ~ 10KG)
110 or less
High (10KG ~ 15KG)
110 or more
Laundry(wet)
L/S valve
Remarks
1
65 or less
2
100 or less
3
175 or less
4
270 or less
5
270 or more
3-1. LOAD SENSING
1) Water level-determining load sensing
1. When the standard, boiling and saving boiling courses are selected, load sensing is performed.
2. Prior to the washing cycle, sensing is performed on dry laundry.
3. After running the motor at 95 rpm, the rotation time for the drum is measured to determine the
amount of laundry.
2) Spin B load sensing
1. After the washing cycle is terminated, in the first medium spinning condition, sensing is performed
on wet laundry.
2. After running the motor at 95 rpm, the rotation time for the drum is measured to determine the
amount of laundry.
3. Depending on the measured amount of laundry, the unbalance reference value for Spin B in the main
spinning cycle and the medium spinning cycle is selected.
3) Load data
1. Water level-determining load data
A value to determine the water level for washing.
2. Spin B laundry data
: Sensing data for selecting a reference value of unbalance in Spin B.
3. Main Function of PCB Program
WFC3V11ZDNH01D2GW(DWC-PS1512X)_칠레향(SM).indd 39
2017-10-26 오후 4:17:40
Summary of Contents for DWC-PS1512X
Page 10: ...8 2 INLET BOX AS WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 8 2017 10 26 오후 4 17 31 ...
Page 12: ...10 3 CABINET F ASSY WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 10 2017 10 26 오후 4 17 32 ...
Page 15: ...13 5 BASE U AS 1 2 3 5 4 WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 13 2017 10 26 오후 4 17 34 ...
Page 69: ...67 6 WIRING DIAGRAM WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 67 2017 10 26 오후 4 17 43 ...