54
3) H5 Error - Water temperature error in wool/ delicate course
①
In case water temperature in wool/ delicate course is 45˚C or higher
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.
4) H6 Error - Abnormality in washing heater
①
Within 15 minutes after heater operation begins;
In case standard temperature is of 42˚C or lower: If temperature does not increase by 2˚C or more In
case standard temperature is higher than 42˚C: If temperature does not increase by1˚C or more
②
If temperature falls below standard temperature by 2˚C or more due to re-supply of water, etc.,
standard temperature is reset as the current temperature and error check time of15 minutes is reset.
③
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④
Error display is cleared when turning off/ on power.
5) H8 Error - Washing heater overheating
①
In case washing heater temperature increases by 5˚C or more within 30 seconds when there is no
water in tank, etc.
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.
WFC3V11ZDNH01D2GW(DWC-PS1512X)_칠레향(SM).indd 54
2017-10-26 오후 4:17:41
Summary of Contents for DWC-PS1512X
Page 10: ...8 2 INLET BOX AS WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 8 2017 10 26 오후 4 17 31 ...
Page 12: ...10 3 CABINET F ASSY WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 10 2017 10 26 오후 4 17 32 ...
Page 15: ...13 5 BASE U AS 1 2 3 5 4 WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 13 2017 10 26 오후 4 17 34 ...
Page 69: ...67 6 WIRING DIAGRAM WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 67 2017 10 26 오후 4 17 43 ...