64
Breakdown
Symptoms
Cause
Diagnosis
Solution
PCB Error
Mode
Washing
water
not heated
(common for
drum)
Wiring short
Check for short
Connect the cut-off
part.
"H6"
Washing heater or
temp. fuse short
Check for short: Normal if 23.3~25.7ohm between
both terminals of washing heater
Replace washing
heater.
"H6"
Connector/ terminal
loosening
Check for loosening: Common for drum
Insert terminal.
"H6"
Defect in washing
heater temp. sensor
Measuring resistance between both terminals of
sensor:
Replace temp. sensor.
"H2"
Overheating of
washing water
Defect in washing
heater temp. sensor
Measuring resistance between both terminals of
sensor:
Replace temp. sensor. "H2" or "H4"
Heater Replacement
* How to Replace Washing Heater and Temp. Sensor
2) Breakdown Diagnosis
1. Remove the connector from the heater.
Unfasten the earth wire
Pull out the thermistor.
2. Heater fix nut is unfasten by tool.
3. Pulling the heater & thermistor
4. Replacing Heater and Temo. Sensor
5. Administer assembly in reverse order and
make sure to fasten heater nuts first before
the earth nuts.
WFC3V11ZDNH01D2GW(DWC-PS1512X)_칠레향(SM).indd 64
2017-10-26 오후 4:17:43
Summary of Contents for DWC-PS1512X
Page 10: ...8 2 INLET BOX AS WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 8 2017 10 26 오후 4 17 31 ...
Page 12: ...10 3 CABINET F ASSY WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 10 2017 10 26 오후 4 17 32 ...
Page 15: ...13 5 BASE U AS 1 2 3 5 4 WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 13 2017 10 26 오후 4 17 34 ...
Page 69: ...67 6 WIRING DIAGRAM WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 67 2017 10 26 오후 4 17 43 ...