2.2.10 Characteristics of the motors, fuses and power cables
Example calculation of a fall in tension
∆
U, of the length and
of the section of the power cable (
∆
U max 5%):
∆
U
= 1.73 • L • Ia • cos
ϕ
/ X • O
|
[V]
L
=
∆
U • X • O
|
/ 1.73 • cos
ϕ
• Ia
[m]
O|
= 1.73 • L • Ia • cos
ϕ
/
∆
U • X
[mm2]
Values in the formula:
∆
U
= Fall in tension
[V]
Ia
= Start-up current
[A]
L
= Length of cable
[m]
O|
= Section of the cable
[mm2]
X
= Conductivity
Cu=57 m/Qmm
cos
ϕ
= Power factor
hoist
drh
Motor
Type
Poles
Group
FEM
Power
(kW)
COS
ϕ
Ia - (A)
400V - 50hz
In - ( A )
400V - 50hz
Power
current
fuse (A)
400V - 50hz
Minimum section
of power cables
400V - (
∆
U20V)
φ
mm
2
L = m
1
112K4RH1/3
4
1Am
3
0.75
40
8
16
2.5
≤
30
2m
3m
112K5RH1/3
4/12
1Am
3/1
0.72/0.5
38/13
8/6.6
16
2.5
≤
30
2m
3m
2
132K4RH2/3
4
1Am
5
0.75
58
12
20
4
≤
30
2m
3m
132K5RH2/3
4/12
1Am
5/1.65
0.78/0.5
50/17
12/10
20
4
≤
30
2m
3m
3
160K4RH3/2
4
1Am
10
0.8
110
22
32
6
≤
30
2m
3m
160K5RH3/2
4/12
1Am
10/3.3
0.77/0.46
100/20
24/18
32
6
≤
30
2m
3m
4
180K4RH4/2
4
1Am
16
0.82
175
34
63
10
≤
20
2m
3m
180K5RH4/2
4/12
1Am
16/5.3
0.78/0.42
170/55
38/30
63
10
≤
20
2m
3m
4
Cylindrical
180C4RH4
4
1Am
2m
3m
24
0.88
330
48
80
16
≤
20
180C5RH4
4/12
1Am
2m
3m
24/7.8
0.88/0.5
330/80
48/32
80
16
≤
20
Trolley
dST
drT
Motor
Type
Poles
Group
FEM
Power
(kW)
COS
ϕ
Ia - ( A )
400V - 50hz
In - ( A )
400V - 50hz
DST 1
DST 2
DRT 1
71K3P
2/8
1Am
2m
3m
0.32/0.07
0.7/0.55
3.8/1.2
1.0/0.8
71C2P
2
1Am
2m
3m
0.32
0.72
6
1.0
71C4P
4
1Am
2m
3m
0.16
0.5
4
1.0
DST 3
DRT 2
80K3P
2/8
1Am
2m
3m
0.5/0.12
0.85/0.6
5.5/1.6
1.3/1.1
80K2P
2
0.50
0.8
5.6
1.3
80K4P
4
0.25
0.65
3.3
0.9
DST 4
* DRT 3
80K3PL
2/8
1Am
2m
3m
0.63/0.15
0.82/0.57
6.8/1.9
1.6/1.3
80K2PL
2
0.63
0.75
7.7
1.7
80K4PL
4
0.32
0.65
3.9
1.1
** DRT 3
*** DRT 4
100K3P
2/8
1Am
2m
3m
1.25/0.31
0.84/0.6
16/3.6
3.1/1.8
100K2P
2
1Am
2m
3m
1.25
0.83
16
2.9
100K4P
4
1Am
2m
3m
0.63
0.8
8.5
1.7
– The articulated DST trolley are realized with 2 motoreducers. Powers stated in the table have to be doubled.
* The trolley DRT3 for hoists DRH4 at 6 ropes falls are realized with 2 motoreducers. The trolley DRT3 for hoist DRH3 at 8 ropes falls and only trolley gauge 2240-2800
is realized with 2 motoreducers. Powers stated in the table have to be doubled.
** The trolley DRT3 for hoists DRH4 4 rope falls, DRH3 6 ropes falls (trolley gauge 1200-1400) and DRH3 8 ropes falls (trolley gauge 1400) are realized with only one
motoreducer.
*** The trolley DRT4 for hoists DRH4 at 8 ropes falls are realized with 2 motoreducers. The powers stated in the table have to be doubled.
MAN16MGO5
35
instructions
for
use
series
drh
1/2/3/4 -
dst
/
n
/
s
-
dst
/
r
-
drt
MAN16MG0
5
The DRH electric wire rope hoists and related trolleys and accessories have been designed and manufactured using
the most modern technical knowledge and can be used safely.
The dangers for persons working with the hoists can be totally eliminated and/or notably reduced only if the hoist is
used by authorised staff who are appropriately trained and sufficiently prepared in accordance with the instructions
in this documentation.
Completing the hoist with any missing parts (electric controls) so as to conform to current legislation.
Setting up the hoist and, the managing of its functioning.
Execution of operations of different kinds on the hoist particularly in relation to maintenance, the checking and the
repair of any of its components before starting up the machine, during its functioning or also after it stops.
Staff must be completely informed about the potential dangers in the execution of their duties, both regarding the
functioning and the correct use of safety measures available on the machine.
These staff must, moreover follow the safety regulations carefully, as described in this chapter, to prevent dangerous
situations occurring.
3. - SAFETY AND ACCIDENT PREVENTION
hoist operator:
Persons qualified to perform simple tasks, that is the driving of the hoist
by use of the controls and the loading and unloading of the materials to
be moved.
OPERATOR
MECHANICAL MAINTENANCE OFFICER
ELECTRICAL MAINTENANCE OFFICER
MECHANICAL TECHNICIAN
ELECTRICAL TECHNICIAN
OPERATOR PROFILE
PICTOGRAM
Mechanical maintenance officer:
Qualified persons able to intervene on the hoist in normal conditions, to
carry out normal adjustments to the mechanisms, ordinary maintenance
checks and mechanical repairs.
Electrical maintenance officer:
Qualified persons able to intervene on the hoist in normal conditions and
for normal interventions of an electrical nature, adjustments,
maintenance and repairs. This person can operate with the presence of
current in the control boards.
Mechanical technician:
Qualified technician authorised to carry out operations of a complex and
exceptional mechanical nature.
Electrical technician:
Qualified technician authorised to carry out operations of a complex and
exceptional electrical nature.
THE STAFF ARE RESPONSIBLE FOR THE FOLLOWING OPERATIONS:
The following table is designed to define more clearly the field of intervention and the consequent assumption of
responsibility of every single operator, given their specific training and qualification obtained. It shows with a
pictogram the professional figures necessary for every kind of intervention.
3.1
Qualifications of qualified operators
KMAN16MG05