WSO Mist Collector, WSO 20, 25-1, 25-2, and 25-3
18
P-Trap Service
1. Place a suitable container under the P-Trap, turn the
collector OFF and remove the pipe plug.
2. Allow fluid and particulate to drain.
3. Use thread sealant and replace pipe plug.
4. Refill the P-Trap with suitable fluid before restarting
the collector.
P-Trap with Y-Strainer, Screen Cleaning and
Removal
1. Place a suitable container under the screen clean-
out valve, turn the collector OFF, close the P-Trap
valve, then open the screen clean-out valve.
2. Allow fluid and particulate to drain.
3. With the clean-out valve open, slowly open the
P-Trap valve. This allows fluid still trapped in the
hopper to drain.
A substantial amount of fluid may
be trapped in the hopper and
could exceed the container capacity. Open the
P-Trap valve slowly.
4. Close the P-Trap valve.
5. Unscrew the screen cap and pull the screen out.
6. Clean the screen and the inside of the Y-strainer
body and re-assemble taking care to seat the screen
in the body and cap.
7. Close the clean-out valve.
8. Open the P-Trap valve.
9. Refill the P-Trap with suitable fluid before restarting
the collector.
pipe plug
P-Trap
strainer screen
P-trap valve
screen
clean-out
valve
P-Trap with Y-Strainer
NOTICE
Summary of Contents for WSO 20
Page 1: ...IOM AK0300801 ENG Revision 3...
Page 5: ...200 Volt 380 Volt 3 Ph 50Hz 60 Hz...
Page 27: ......
Page 31: ......