Donaldson Company, Inc.
Site Selection, Ceiling-Mounted Units
(WSO 20 and 25-1):
Lifting lugs on the unpowered unit
(25-2 or 25-3) are not intended
for ceiling suspension. Unit is floor-mount only.
Failure to comply may result in personal injury
and/or property damage.
Ensure weight of oil-laden unit plus weight
of required materials and equipment will
be adequately supported. Failure to comply
may result in personal injury and/or property
damage.
WSO 20 and 25-1 can be suspended or hung from
overhead supports. The supports must be adequate to
carry the live load of the unit and installation performed
to reduce sway or vibration to the unit. The dry unit
weight is shown on the specification control drawing
shipped with the unit.
The live load will include the weight of all ancillary
hardware attached to the mist collector, as well as the
weight of the mist-laden, wet filters. Consult the coolant
MSDS for the specific gravity of the coolant to estimate
the weight of the mist-laden, wet filters.
Provide clearance from heat sources and interference
with utilities when selecting the location for suspended
units.
Unit Location
Donaldson Torit equipment
is not designed to support
site-installed ducts, interconnecting piping,
or electrical services. All ducts, piping, or
electrical services supplied by others must
be adequately supported to prevent severe
personal injury and/or property damage.
When hazardous conditions or materials are
present, consult with local authorities for the
proper location of the collector.
If combustible materials will
be processed through this
collector, local codes may require the collector
be located either outside or adjacent to an
exterior wall to accommodate devices related
to a fire or explosion mitigation strategy.
Consult local codes prior to installation.
Foundation or overhead (for WSO 20 and 25-1) support
must be sized to accommodate the entire weight of the
unit, plus the weight of the collected material, piping,
and ductwork.