47
47
47
47
16
16
16
16
MODULE
MODULE
MODULE
MODULE MAI
MAI
MAI
MAINTE
NTE
NTE
NTEN
N
N
NANCE
ANCE
ANCE
ANCE
To maintain the moduel in perfect working order, a yearly service should be performed by personnel
authorised by
DOMUSA TEKNIK
DOMUSA TEKNIK
DOMUSA TEKNIK
DOMUSA TEKNIK
.
Module
Module
Module
Module and fl
and fl
and fl
and flue maintenance
ue maintenance
ue maintenance
ue maintenance
The most important aspects to be checked are as follows:
- The water pressure in the heating installation,
whe
whe
whe
when
n
n
n the water is cold
the water is cold
the water is cold
the water is cold
, must be between 0.1
and 0.15 MPa (1 and 1.5 bar). If it is not between these values, it must be filled until they are
reached.
- The control and safety devices (thermostats, gas valve, etc.) must operate correctly.
The burner and the inside of the combustion chamber must be clean. Soft brushes or
compressed air are recommended for cleaning the module, to prevent damage.
Do not use
Do not use
Do not use
Do not use
ch
ch
ch
chemical products.
emical products.
emical products.
emical products.
.
The expansion vessel must be full, in accordance with the specifications on the vessel plate.
Check the gas and water installations are completely sealed.
The flues must be free of any obstacles and have no leaks.
The gas flow must remain between the values indicated on the
Technical Data Sheet
Technical Data Sheet
Technical Data Sheet
Technical Data Sheet
.
.
The circulating pumps and mixer valves must not be blocked.
Cleaning the b
Cleaning the b
Cleaning the b
Cleaning the burner and combustion chamber
urner and combustion chamber
urner and combustion chamber
urner and combustion chamber
The module does not require any special maintenance. A
yearly clean
yearly clean
yearly clean
yearly cleaning procedure
ing procedure
ing procedure
ing procedure
at the end of
the heating season will be enough.
The
The
The
The combustion
combustion
combustion
combustion chamber
chamber
chamber
chamber and burner should not be clea
and burner should not be clea
and burner should not be clea
and burner should not be cleaned
ned
ned
ned
using
using
using
using chemical products or steel brushes.
chemical products or steel brushes.
chemical products or steel brushes.
chemical products or steel brushes.
After any cleaning operation has been carried out, it is
important to run several ignition cycles to check all the elements are operating correctly.
After checking the module is functioning correctly, ensure there are no leaks.
Draining the condensation water
Draining the condensation water
Draining the condensation water
Draining the condensation water
The module condensation water drain outlet should not be altered in any way and it must be kept
free of obstructions. It is advisable to perform an annual cleaning procedure of the condensation
collection siphon.
If a neutralisation system is installed at the condensation drain outlet, it should undergo periodical
maintenance, in accordance with the manufacturer's instructions.
Cleaning prod
Cleaning prod
Cleaning prod
Cleaning products
ucts
ucts
ucts
Never use chemical products to clean the module. A plastic brush is enough, if the cleaning is
carried out annually.
The cleaning of the module and hydraulic circuit will have lasting effects if water with a hardness of
over 25ºF is treated previously. For softer water no treatment is required. In any case, a descaling
pump should be used to carry out the descaling process.