EN
30
DUAL CLIMA R
6.6.6
Connecting a backup source of energy for Heating installation (E2)
The
DUAL CLIMA R
heat pump allows the connection of a backup electrical heater for Heating
installation (optional). Within the wide range of accessories for heat pumps,
DOMUSA TEKNIK
offers
the optional HP Hydraulic Kit that includes a heating electrical heater (2,500 W).
The electrical connection of the heater will be made between terminals
E2L
and
N
(Neutral) of the
component terminal of the heat pump.
The relay that activates the electrical heater has a maximum capacity of 20 A of consumption.
Therefore, to connect a heater exceeding 4,500 W, a contactor must be interposed between the
terminals of the power terminal and the heater.
As alternative to the backup electrical heater,
DUAL CLIMA R
heat pump allows the connection of a
conventional source of energy as gas boiler, oil boiler, biomass, etc. For it, the heating installation must
be provided with an auxiliary system of water heat exchange that allows the hydraulic connection of
the above mentioned backup source of energy, preferably it should be independent from the water
circuit of the heat pump.
They are used the same terminals
E2L
and
N
(Neutral) of the components powerstrip to make the
connection between the backup source of energy and the heat pump. Depending on the installation
characteristics and the type of the backup boiler, the electrical connection could be made at least by 2
different ways:
Direct connection
In this type of connection it is used the powered output of
E2
relay (230 V~; maximum 20A) to activate
directly the backup energy source (switch on the boiler, activate the backup circulating pump, etc.).
For it, connect the terminals
E2L
and
N
of the heat pump to the main power supply input of the backup
boiler and/or of the device of the installation provided.
NOTE: When the backup source of energy is connected, it has to be taken in account that
the maximum capacity of E2 relay is 20 A.
E1L
E2L N C4L N C6L L G2S G3S
H COM
N C
N
N
L
E1L
E2L N
N
Summary of Contents for DUAL CLIMA R
Page 1: ...DUAL CLIMA R Air to Water Heat Pump EN INSTALLATION AND OPERATION INSTRUCTIONS ...
Page 54: ...EN 54 DUAL CLIMA R 14 2 Dual Clima 6R ...
Page 55: ...55 DUAL CLIMA R 14 3 Dual Clima 9R ...
Page 56: ...EN 56 DUAL CLIMA R 14 4 Dual Clima 12R ...
Page 57: ...57 DUAL CLIMA R 14 5 Dual Clima 16R ...
Page 58: ...EN 58 DUAL CLIMA R 14 6 Dual Clima 19R ...
Page 59: ...59 DUAL CLIMA R 14 7 Dual Clima 16RT ...
Page 60: ...EN 60 DUAL CLIMA R 14 8 Dual Clima 19RT ...
Page 69: ...69 DUAL CLIMA R DUAL CLIMA 9R ...
Page 70: ...EN 70 DUAL CLIMA R DUAL CLIMA 12R ...
Page 71: ...71 DUAL CLIMA R DUAL CLIMA 16R ...
Page 72: ...EN 72 DUAL CLIMA R DUAL CLIMA 19R ...
Page 73: ...73 DUAL CLIMA R DUAL CLIMA 16RT ...
Page 74: ...EN 74 DUAL CLIMA R DUAL CLIMA 19RT ...
Page 81: ...81 DUAL CLIMA R NOTES ...
Page 82: ...EN 82 DUAL CLIMA R NOTES ...
Page 83: ...83 DUAL CLIMA R NOTES ...