CONFIGURING THE HEAT PUMP
The
DUAL CLIMA R
heat pump is supplied from factory configured to provide Heating, Cooling and DHW
modes. In case the installation does not have any of these services allowed,
THEY MUST
be disabled
by
adjusting the parameters in the control unit (see
"Settings menu"
). When any mode is disabled, all the
settings and parameters related to this operating mode will disappear from the main board display.
Disabling the DHW mode
If the installation does not have an storage tank for the production of DHW, this mode must be disabled.
To disable this feature, parameter
P56
of the Service Menu must be adjusted (see
"Service Menu"
). The
heat pump is supplied by default with the DHW service enabled. To disable it, set parameter
P56
to value
0
. Furthermore, it will be necessary to disconnect the heat pump from the mains and reconnect it to
validate this change.
Disabling the Heating mode
If the installation does not have a water circuit ready to operate in heating mode (underfloor heating,
radiators, etc.), this mode must be disabled. To disable this feature, parameter
P55
of the Technician
Menu must be adjusted (see
"Technician Menu"
). The heat pump is supplied by default with the heating
service enabled. To disable it, set parameter
P55
to value
0
. Furthermore, it will be necessary to
disconnect the heat pump from the mains and reconnect it to validate this change.
Disabling the Cooling mode
If the installation does not have a water circuit ready to operate in the cooling mode (cooling floor, fan
coils, etc.), this mode must be disabled. To disable this feature, parameter
P54
of the Technician Menu
must be adjusted (see
"Technician Menu"
). The heat pump is supplied by default with the cooling service
enabled. To disable it, set parameter
P54
to value
0
. Furthermore, it will be necessary to disconnect the
heat pump from the mains and reconnect it to validate this change.
IMPORTANT: Keeping a mode enabled without the installation being prepared to operate
with it may cause a malfunction of the heat pump and SERIOUS damage to
the installation.
Summary of Contents for DUAL CLIMA R
Page 1: ...DUAL CLIMA R Air to Water Heat Pump EN INSTALLATION AND OPERATION INSTRUCTIONS ...
Page 54: ...EN 54 DUAL CLIMA R 14 2 Dual Clima 6R ...
Page 55: ...55 DUAL CLIMA R 14 3 Dual Clima 9R ...
Page 56: ...EN 56 DUAL CLIMA R 14 4 Dual Clima 12R ...
Page 57: ...57 DUAL CLIMA R 14 5 Dual Clima 16R ...
Page 58: ...EN 58 DUAL CLIMA R 14 6 Dual Clima 19R ...
Page 59: ...59 DUAL CLIMA R 14 7 Dual Clima 16RT ...
Page 60: ...EN 60 DUAL CLIMA R 14 8 Dual Clima 19RT ...
Page 69: ...69 DUAL CLIMA R DUAL CLIMA 9R ...
Page 70: ...EN 70 DUAL CLIMA R DUAL CLIMA 12R ...
Page 71: ...71 DUAL CLIMA R DUAL CLIMA 16R ...
Page 72: ...EN 72 DUAL CLIMA R DUAL CLIMA 19R ...
Page 73: ...73 DUAL CLIMA R DUAL CLIMA 16RT ...
Page 74: ...EN 74 DUAL CLIMA R DUAL CLIMA 19RT ...
Page 81: ...81 DUAL CLIMA R NOTES ...
Page 82: ...EN 82 DUAL CLIMA R NOTES ...
Page 83: ...83 DUAL CLIMA R NOTES ...