51
It is preferable for each machine to have its own separate steam outlet. If this is not possible:
It is
COMPULSORY
to install a check valve for each of the machines before reaching the
head pipe.
Connections always in Y, never in T.
Increase the section before connection so that the final section is the sum of the two previous
ones.
IMPORTANT
: Some fresh air inlets must be foreseen in the room to allow the inlet of the
volume of air that has to be extracted (see section 3.2.1).
A table is included below where the equivalent diameter necessary can be consulted when
connecting several dryers to one common steam outlet and the minimum fresh air inlet area (see
section 3.2.1):
Number of dryers
1
2
3
4
5
6
7
8
9
10
Diameter of the output
pipe (mm)
200 300 350 400 450 500 500 560 600 630
Minimum area of the
fresh air inlet to the
premises (m²)
0,15 0,25 0,40 0,50 0,65 0,80 0,80 1,00 1,15 1,25