EN
CombiPower
Configuring the device with the remote control
93
9.2
Overview of parameters
“Change Run Mode” menu (operating mode)
“P.S. Mode Param” menu (power sharing mode)
Parameter
Explanation
COMBI Power On
The device acts as a charger and, if necessary, as an
inverter if there is not sufficient current at the AC input.
CHR Power On
The device only acts as a charger. The inverter function is
deactivated.
Parameter
Explanation
Value range
Default
Iac setup
Power sharing level: limits the
current at the 230 V input (over-
load protection).
3 A – 25 A
3 A
Power
Sharing
Determines the power sharing
mode:
Disable = deactivated
GEN. = generator function
SUPP. = support function
SHAR. = power sharing
“SHAR.” enables the power
sharing function.
“SHAR. GEN.” enables the
power sharing and generator
functions.
“SHAR. SUPP.” enables the
power sharing and support func-
tions.
“SHAR. SUPP. GEN.” enables
the power sharing, support and
generator functions.
Disable
SHAR.
SHAR. GEN.
SHAR. SUPP.
SHAR. SUPP. GEN.
Disable
_CombiPower_IA_DE-IT.book Seite 93 Freitag, 21. Oktober 2011 8:10 20