Top Center Hole
of Filter
DO:
1. Change the cartridge filters regularly
2. Monitor the system and keep a daily log
3. Adjust the system product to the recommended value
4. Always feed the pump with filtered water
:
1. Permit chlorine to be present in the feed water
2. Shut down the system for extended periods of time without preservation
3. Close the pressure valves completely
4. Operate the system with insufficient feed flow
5. Operate the pump dry
Initial Startup
Carefully inspect your system before initial start-up. Check that all plumbing and electrical
connections are not lose
Filter Housing Wrench will accompany your SZIII-Series Reverse Osmosis System.
1. Maintain the permeate water line (Product to Tank) to drain for this procedure.
2. Flush the provided 252404301 filter cartridges, then install into the housing. Be sure to flush
outside of the system to prevent carbon dust from fouling the membranes. See the figures
below on how to properly flush the filters.
NOTE
If you are using the short double pre-filters (part number 252404004 and 252404005) there
will be two filter housings that are used. Only 252404004 needs to be flushed before
inserting it into the housing.
Freshwater Hose
Proper Way to Flush 252404301
Proper Way to Flush 252404004
32
Summary of Contents for SPOTZERO SZIII 2000
Page 1: ...USER MANUAL INSTALLATION GUIDE SZIII 2000 3000 www spotzerowater com ...
Page 4: ... Introduction 4 ...
Page 8: ...Installation and Commissioning 8 ...
Page 13: ...13 ...
Page 17: ...Membrane Return Membrane Product assemblies Membrane Assembly 17 ...
Page 18: ...Operation and Maintenance 18 ...
Page 35: ...35 ...
Page 42: ...Troubleshooting 42 ...
Page 46: ...SZIII System Specification and Parts 46 ...
Page 47: ...47 ...
Page 48: ...48 ...
Page 49: ...49 ...
Page 50: ...50 ...
Page 51: ...51 ...
Page 52: ...52 ...
Page 53: ...53 ...
Page 54: ...54 ...
Page 55: ...Warranty 55 ...