Installing the switching power supply
SMP301
20
➤
Press the two tabs (fig.
3, page 8) in the direction indicated by the arrows and
lift the cover off (fig.
➤
Connect the positive terminal of the consumer units to the flat plugs P1–P5
(fig.
➤
Connect the negative terminal of the consumer units to one of the flat plugs P7
(any pin) (fig.
➤
Connect the AC connection cable to the AC plug.
➤
Secure all cables with strain relief clamps.
SMP301-01/ -03/ -04/ -05/ -07/ -10
Please note that flat plugs P1–P6 are individually fused via plug-in fuses F1–F6 in the
following manner:
➤
Press the two tabs (fig.
3, page 8) in the direction indicated by the arrows and
lift the cover off (fig.
➤
Connect the positive terminal of the consumer units to the flat plugs P1–P6
(fig.
➤
Connect the negative terminal of the consumer units to one of the flat plugs P7
(any pin) (fig.
➤
Connect the positive terminal of the battery to one of the flat plugs P6.
–
SMP301-01/ -03/ -04/ -05/ -10: z. B. fig.
–
SMP301-07: fig.
➤
Connect the negative terminal of the battery to one of the flat plugs P7 (any pin).
–
SMP301-01/ -03/ -04/ -05/ -10: z. B. fig.
–
SMP301-07: fig.
Flat plug
Fuse
Fuse assignment
Maximum permissi-
ble current
P1
F1
10 A
15 A
P2
F2
10 A
15 A
P3
F3
5 A
15 A
P4
F4
5 A
15 A
P5
F5
10 A
15 A
P6
Only SMP301-07
F6
20 A
20 A