Smart Touch Cabin Control Installation & Operations Manual
OPERATION
L-3380 ENGLISH
23
Control
Parameters
(continued)
DX Operational
Settings
Page 1
Compressor Start Delay
5 sec
135 sec
15 sec
Failsafe Level
Faults Not Detected / Faults Detected But
Not Displayed / Faults Detected and
Displayed / Faults Detected and
Displayed with Lockout
Faults Detected and
Displayed with Lockout
Low-Voltage Monitor
Off/75-120V AC or Off/175-240V AC
Off
Page 2
De-Ice Cycle
Disabled / Enabled with 5°F/3°C Sensor
Differential / Enabled with 7°F/4°C
Sensor Differential
Enabled with 5°F/3°C
Sensor Differential
Pump Sentry
Off/100-150°F or Off/40-65°C
Off
Pump Operational Mode
Continuous or Cycled
Continuous
Page 3
Low Pressure Detection
Set by Jumper / Disabled
Set by Jumper
CW Operational
Settings
Page 1
Water Valve Force Open
Off/On
Off
Water Temp Differential
5°F/3°C
25°F/14°C
15°F/8°C
Page 2
Memorize Settings
Recall Memorized
Settings
Recall Factory
Default Settings
Table 1: Main Menu – Programmable Parameters (continued)
Main
Category
Item
Sub Item 1
Sub Item 2
Sub Item 3
Range
(min/max) or
Choices
Factory Default