background image

2 -

 WAY display panel.

START 

UP INSTRUCTIONS

A. A 12 volt DC supply must be available for the

electronic control to function.

B. Press the main power ON/OFF button (1) to the

DOWN position.

C. Press the TEMPERATURE SELECTOR BUTTON (3)

P-WAY Model or (4) 3-WAY Model until the lamp at

the desired setting is illuminated.

2-WAY MODEL

AUTO MODE

1. Move the AUTO/GAS mode selector button (2) to

the DOWN position. (If 120 volts AC is available, the

AC mode indicator lamp (B) will illuminate indicat-

ing AC operation. If 120 volts AC is not available, the

GAS mode indicator lamp (C) will illuminate and the

control system will automatic switch to GAS opera-

tion.

2. If the CHECK indicator lamp (E) illuminates and the

GAS mode indicator lamp (C) is off, the controls

have failed to ignite the burner in the GAS mode.
GAS operation may be reset by pressing the main

power ON/OFF 

button 

(1) to the OFF than ON posi-

tion. (see step 2 under GAS MODE)

3. Press the TEMPERATURE SELECTOR button (3)

until the lamp at the desired position is illuminated.

GAS MODE

1.

Move the AUTO/GAS mode selector button (2) to

the UP position_ The GAS mode indicator lamp (C)

will illuminate. After 45 seconds the burner should

be ignited and operating normally.

2. On the initial refrigerator start-up, it may take longer

than 45 seconds to allow air to be purged from the

gas line. If the gas does not ignite within 45 seconds

the CHECK indicator lamp (E) will illuminate and the

GAS mode indicator lamp (C) will go off. To reset

when the CHECK indicator lamp (E) is illuminated,

press the main power ON/OFF button (1) to the OFF

and then ON position.

NOTE: Do not continue to reset GAS operation if the

CHECK indicator lamp continues to be illuminated after

several tries.

3. Press the TEMPERATURE SELECTOR button (3)

until the lamp at the desired position is illuminated.

TO SHUT OFF THE REFRIGERATOR

The refrigerator may be shut off while in any mode of

operation by pressing the main power ON/OFF button

to the UP (OFF) position. This shuts off all DC power to

the refrigerator.

3 - WAY 

display panel.

1.

2.

3.

4.

1.

2.

3.

3-WAY MODEL

AUTO MODE

Press the DC mode selector button (2) to the UP

(OFF) position.

Move the AUTO/GAS mode selector button (3) to

the DOWN position. (If 120 volts AC is available, the

AC mode indicator lamp (B) will illuminate indicat-

ing AC operation. If 120 volts AC is not available, the

GAS mode indicator lamp (C) will illuminate and the

control system will automatic switch to GAS opera-

tion.

If the CHECK indicator lamp (E) illuminates and the

GAS mode indicator lamp (C) is off, the controls

have failed to ignite the burner in the GAS mode.

GAS operation may be reset by pressing the main

power ON/OFF button (1) to the OFF than ON posi-

tion. (see step 2 under GAS MODE)

Press the TEMPERATURE SELECTOR button (4)

until the lamp at the desired position is illuminated.

GAS MODE

Press the DC mode button (2) to the UP (OFF) posi-

tion.

Move the AUTO/GAS mode selector button (3) to

the UP position. The GAS mode indicator lamp (C)

will iliimunate. After 45 seconds the burner should

be ignited and operating normally.

On the initial refrigerator start-up, it may take longer

than 45 seconds to allow air to be purged from the

gas line. If the gas does not ignite within 45 seconds

the CHECK indicator lamp (E) will illuminate and the

GAS mode indicator lamp (C) will go off. To reset

when the CHECK indicator lamp (E) is illuminated,

press the main power ON/OFF button (1) to the OFF

and then ON position.

NOTE: Do not continue to reset GAS operation if the

CHECK indicator lamp continues to be illuminated after

several tries.

4. Press the TEMPERATURE SELECTOR button (4)

until the lamp at the desired position is illuminated.

DC MODE

1. 

Press the DC mode indicator button (2) to the down

position.

2. Press the TEMPERATURE SELECTOR button (4)

until the lamp at the desired position is illuminated.

10

Summary of Contents for Silhouette S1521

Page 1: ...installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agenc...

Page 2: ...AUTO Mode Indicator Lamp E CHECK Indicator Lamp GAS Mode Only F Temperature indicator Lamps PROTECTION PLATE FIG 2 F LEGEND 3 WAY AMES Model 1 Main Power Button ON OFF 2 DC Mode Selector Button 3 AUT...

Page 3: ...on An opening toward the out side at floor level in the refrigerator compartment must be provided for ventilation of heavier than air fuel gases The lower vent of the recommended kiis is provided with...

Page 4: ...alled must be sealed Make sure that there is a complete seal between the front frame of the refrigerator and the top sides and bottom of the enclosure A length of sealing strip is applied to the rear...

Page 5: ...ondenser and absorber tubes see FIG 6 must receive a continual supply of cooler air in order to main tain proper refrigerator cooling A recommended 0 clearance between the back of the refrigerator and...

Page 6: ...3 Bend the panel gently so that the free side of the panel can be slipped into the corresponding groove of the door frame 4 Slide the panel down into the groove of the bottom frame 5 Between the upper...

Page 7: ...be leveled only so it is comfortable to live in no noticeable sloping of floor or walls When the vehicle is moving the leveling is not critical as the rolling and pitching movment of the vehicle will...

Page 8: ...TO SHUT OFF THE REFRIGERATOR The refrigerator may be shut off while in any mode of operation by pressing the main power ON OFF button to the UP OFF position This shuts off all DC power to the refriger...

Page 9: ...mode indicator lamp A will be illuminated All other mode lamps will be off The DC mode overrides all other operating modes If one of the other operating modes is desired the DC selector button 2 must...

Page 10: ...thermostat is set at its highest position It is a good idea to do this a few hours before the an ticipated need for ice but be sure to move back to nor mal setting usually about mid setting when the...

Page 11: ...and the 12 volt wires 2 Remove the power module cover See FIG 1 3 Snap the fuse out of the fuse holder 4 Fit a new fuse in to the fuse holder 5 Replace the power module cover 1 2 A MAINTENANCE SERVICE...

Page 12: ...th a brush Blow out bumerwith compressed air Before removing burner jet clean burner area of soot and scale that fell out of flue tube Remove the burner jet Soak the jet in wood alcohol and blow it ou...

Page 13: ...flue tube see side 3 FIG 1 2 4 Burner dirty Clean See Section Maintenance ser vice item 2 Periodic Maintenance Paragraph E item 8 2 5 LP gas pressure low at burner Set main regulator so pressure does...

Page 14: ......

Reviews: