if. A minimum of 9.6 volt DC supply present for the
refrlgerator control system.
lg. The thermostat can not be moved from MID posi-
tion to the desired setting. The display module has
became nonfunctional. See limp mode of operation
(side 11).
1 h. The refrigerator is running continuously and cool to
much.
The temperature sensing device has became non
functional. See limp mode of operation (side 11).
2. Gas operation only.
2.1 The refrigerator will not operate on gas when AC is
present.
The display module has became non functional. See
limp mode of operation (side 11).
2.2 Burner jet clogged. Clean see Section Main-
tenance/service, item 2. Periodic maintenance,
Paragraph E. item 9.
2.3 flue baffle not inserted properly in flue tube (see
side 3 FIG. 1).
2.4 Burner dirty. Clean. See Section Maintenance/ser-
vice, item 2. Periodic Maintenance, Paragraph E.
item 8.
2.5 LP gas pressure low at burner.
Set main regulator so pressure does not drop below
11 inches water column at pressure test port (see
side 13 FIG. 16).
2.6 Burner not located properly under flue tube, relo-
cate.
2.7 Burner damage, replace.
ODOR FROM FUMES
CAUSES AND REMEDIES
A. The flame touches side
of
the
boiler due to disloca-
tion of the burner. Relocate. Burner dislocation may
also cause smoke and discoloring of walls and ceil-
ing.
B. Burner damaged. Replace.
All the above instructions are to be followed closely. The
refrigerator is quality-guaranteed. However, we are not
responsible for any failures caused by improper adjust-
ments and unfavorable installation conditions. Contact
service point or distributor service dept. for assistance.
Replacement Parts Suppliers: See page 1.