background image

8

Check burner flame 

Check burner flame for proper  
appearance. The flame should be  
light blue with no yellow at the tip.
 
 

Check the LP gas pressure 

The LP gas pressure should be checked and the main regulator 
readjusted if pressure is incorrect. The correct operating pres-
sure is 11 inches of water column. The correct place to take the 
LP gas pressure is at the test port just ahead of the burner jet.

mAINTENANCE & SERVICE

Inspect the flue baffle

It should be reasonably clean and free of soot. Heavy soot for-
mation indicates improper functioning of the burner. The flue 
and burner both require cleaning in the following manner:

Unplug the refrigerator power cord from the 120 volt 

1. 

AC outlet.
Turn the knob (

2. 

A

) to “

OFF

” position.

Remove cover from the burner housing.

3. 

Disconnect the wire from the high voltage electrode.

4. 

Remove the burner mounting screw and remove the 

5. 

burner assembly.
Remove the wire and flue baffle from the top of flue 

6. 

tube. Clean the flue from the top using a  flue brush. 
Blowing compressed air into the flue 

will not 

prop-

erly clean soot and scale out of the flue tube. Replace 
the flue baffle.
Clean burner tube with a brush. Blow out burner with 

7. 

compressed air.
Before removing burner jet, clean burner area of soot 

8. 

and scale that fell out of flue tube. Remove the burner 
jet. Soak the jet in wood alcohol and blow it out with 
compressed air. Re-install and tighten burner jet.

Clear blue 
color of 
flame

Spring

Thermocouple

connection

Pressure test port

Burner jet

Burner mounting screw

Spark electrode

Burner tube

Thermocouple

Electrode

Burner tube

1/8” to 3/16”

(3-5 mm)

FIrE hAZArD. Do not use a wire or pin when 
cleaning the burner jet as damage can occur to 
the precision opening. Failure to heed this warn-

ing could cause fire resulting in personal injury.

WARNING

!

Reinstall burner, being careful that the end of the 

9. 

burner fits into the slot on the burner bracket. Check 
to make sure slots are centered under the flue tube 
and the thermocouple is positioned properly (tip of 
thermocouple extends over two slots of burner). 
Be sure to reconnect the wire to high voltage elec-

10. 

trode. Check the electrode for proper location and 
gap.  
 
 
 
 
 
 
 

The gas fittings on the refrigerator need to be 

11. 

checked for leaks. Turn the knob (

A

) to position 

GAS

”. Apply a non-corrosive bubble solution to the 

fitting and observe for leaks. The safety valve will 
not allow gas pressure to any connections between 
it and the burner jet. These fittings must be checked 
before burner is lighted. 
 

The safety shut-off must be manually  

depressed to allow gas pressure to flow to the 

burner jet. be sure to apply the leak check 

solution before depressing the safety shut-off. 

DO NOT depress safety shutoff for over 30 

seconds. 

 

 

 

 

 

 

 

 

 

Allow 10 minutes for the LP gas to leave the burner 

12. 

area. Light the burner according to the “Operating 
Instructions” section “Gas Operation”. Allow burner 
to run 5 minutes.
Connect 120 volt power cord to the outlet.

13. 

Check LP gas safety shutoff.

14. 

EXPLOSION hAZArD. Never use an open 

flame to check for gas leaks. Failure to heed this 

warning could cause an explosion resulting in 

death or severe personal injury.

WARNING

!

Summary of Contents for Servel RGE400

Page 1: ...re fournisseur de gaz FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Pour votre s curit Ne pas entreposer ni utiliser...

Page 2: ...________________ 7 Periodic maintenance 7 Lighting 7 Shut off storage procedure 7 Troubleshooting 9 Spare parts 9 WIRING DIAGRAM______________________________ 9 Symbols The following symbols are used...

Page 3: ...s fuel for a free standing installation The installation must conform with local codes or in absence of local codes the following standards as applicable Free standing model for floor installation onl...

Page 4: ...e routed to avoid direct contact with the burner cover flue cover or any other components that could damage the cord insulation Refrigerator removal Before working on the refrigerator make sure the AC...

Page 5: ...h button 3 C in until it bottoms out and hold While holding button C push button D for the piezo igniter several times to light the burner This can be observed through the flame view port E After the...

Page 6: ...ads etc should be covered to retain their crispness The coldest positions in the refrigerator are under the cooling fins and at the bottom of the refrigerator The warmer areas are on the upper door sh...

Page 7: ...er should be aware of service that must be done on a regular schedule to keep the refrigerator operating properly A qualified technician who is familiar with LP gas systems and refrigerators should on...

Page 8: ...ure test port Burner jet Burner mounting screw Spark electrode Burner tube Thermocouple Electrode Burner tube 1 8 to 3 16 3 5 mm FIRE HAZARD Do not use a wire or pin when cleaning the burner jet as da...

Page 9: ...rts which will be available if required from your Dometic Service Cen ter Part No Description 200 74 19 21 7 Jet no 58 200 75 03 03 6 Burner with electrode 293 03 79 00 9 Electrode 293 14 96 04 2 Ther...

Page 10: ...e l arr t p riode d inactivit 15 MAINTENANCE ET ENTRETIEN__________________ 15 Maintenance p riodique 15 D pannage 17 Pi ces de rechange 17 Sch ma leqtrique_________________________ 17 Symboles Les sy...

Page 11: ...ratures ambiantes lev es il faut galement pr voir une circulation libre de l air au dessus de l unit r frig rante situ e derri re l appareil Assurez vous qu il reste un espace libre minimum de 4 pouc...

Page 12: ...et D Appliquez une solution bulles de savon du commerce non corrosive sur la buse du br leur Aucune bulle ne doit appara tre l orifice de la buse 6 La pr sence de bulles indique un d faut de fonction...

Page 13: ...n 2 B du thermostat sur la position 4 Enfoncez le bouton 3 C fond puis en le maintenant ainsi poussez plusieurs reprises le bouton D de l allumoir pi zo pour allumer le br leur L allumage du br leur p...

Page 14: ...sition m diane d s que la glace se sera form e Les aliments dans le compartiment inf rieur pourraient geler si le bouton restait sur la position de r glage MAX D givrage Le givre ne doit pas pouvoir s...

Page 15: ...sement peut provoquer une explosion avec des risques d accident mortel ou de graves blessures N B Du chromate de sodium est utilis comme protection contre la corrosion moins de 2 pour cent en poids du...

Page 16: ...la pression du GLP propane V rifier la pression du GLP propane et r gler de nouveau le r gulateur principal si la pression n est pas correcte La pres sion de service qui convient est de 11 pouces de...

Page 17: ...ange La liste suivante indique les pi ces habituellement utilis es et pouvant tre disponibles en cas de besoin aupr s de votre centre d entretien Dometic N de r f rence Description 200 74 19 21 7 Buse...

Page 18: ...s of this Warranty the Original Purchaser should contact their selling dealer If none is available you may call for the location of a service center at 1 800 544 4881 In Canada call 1 519 653 4390 Be...

Page 19: ...ty Registration Form an a check Mastercard Visa or Discover card number covering the charge for the DOMETICARE coverage Any cooling unit which is replaced will not be returned to the Original Purchase...

Page 20: ...Please Process At Once Name_ _____________________________ Address_ __________________________ City ST Zip_ _______________________ Please check here if new address TO THE INSTALLER PLEASE AFFIX THESE...

Reviews: