background image

10

TAbLE DES mATIERES

INSTALLATION _______________________________ 11

Informations  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11
Modèle indépendant pour installation uniquement au sol  .  .  .  . 11
Distances de dégagement  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11
Dimensions du réfrigérateur   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 12
Raccordement du gaz  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 12
Essai de l’arrêt de sécurité du gpl (propane)  .  .  .  .  .  .  .  .  .  .  .  .  .  . 12
Raccordement électrique  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 12
Déplacement du réfrigérateur  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 12

CONSIGNES D’UTILISATION ___________________ 13

Importance d’une bonne mise à niveau du réfrigérateur  .  .  .  .  . 13
Dispositifs de commande   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 13
Utilisation au gaz  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 13
Utilisation électrique   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 13

Thermostat   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 13
Nettoyage   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14
Éclairage intérieur  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14
Comment utiliser le réfrigérateur  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14
Mise à l’arrêt - période d’inactivité  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 15

mAINTENANCE ET ENTRETIEN _________________ 15

Maintenance périodique   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 15
Dépannage  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 17
Pièces de rechange  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 17

SChémA éLEqTRIqUE ________________________ 17

SymbOLES

Les symboles suivants sont employés dans tout le manuel:

Indique une situation potentiellement dangereuse qui, si elle n’est pas évitée, pourrait en-
traîner de graves blessures ou même la mort.

Indique une situation potentiellement dangereuse qui, si elle n’est pas évitée, pourrait 
résulter en des blessures mineures ou modérées.    

 

  

Utilisé sans le symbole d’alerte à la sécurité, indique une situation potentiellement dan-
gereuse qui, si elle n’est pas évitée, pourrait résulter en des dommages matériels.

Information

Instructions pas à pas

ATTENTION

!

ATTENTION

AVERTISSEMENT

!

GARANTIE __________________________________ 18

Summary of Contents for Servel RGE400

Page 1: ...re fournisseur de gaz FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Pour votre s curit Ne pas entreposer ni utiliser...

Page 2: ...________________ 7 Periodic maintenance 7 Lighting 7 Shut off storage procedure 7 Troubleshooting 9 Spare parts 9 WIRING DIAGRAM______________________________ 9 Symbols The following symbols are used...

Page 3: ...s fuel for a free standing installation The installation must conform with local codes or in absence of local codes the following standards as applicable Free standing model for floor installation onl...

Page 4: ...e routed to avoid direct contact with the burner cover flue cover or any other components that could damage the cord insulation Refrigerator removal Before working on the refrigerator make sure the AC...

Page 5: ...h button 3 C in until it bottoms out and hold While holding button C push button D for the piezo igniter several times to light the burner This can be observed through the flame view port E After the...

Page 6: ...ads etc should be covered to retain their crispness The coldest positions in the refrigerator are under the cooling fins and at the bottom of the refrigerator The warmer areas are on the upper door sh...

Page 7: ...er should be aware of service that must be done on a regular schedule to keep the refrigerator operating properly A qualified technician who is familiar with LP gas systems and refrigerators should on...

Page 8: ...ure test port Burner jet Burner mounting screw Spark electrode Burner tube Thermocouple Electrode Burner tube 1 8 to 3 16 3 5 mm FIRE HAZARD Do not use a wire or pin when cleaning the burner jet as da...

Page 9: ...rts which will be available if required from your Dometic Service Cen ter Part No Description 200 74 19 21 7 Jet no 58 200 75 03 03 6 Burner with electrode 293 03 79 00 9 Electrode 293 14 96 04 2 Ther...

Page 10: ...e l arr t p riode d inactivit 15 MAINTENANCE ET ENTRETIEN__________________ 15 Maintenance p riodique 15 D pannage 17 Pi ces de rechange 17 Sch ma leqtrique_________________________ 17 Symboles Les sy...

Page 11: ...ratures ambiantes lev es il faut galement pr voir une circulation libre de l air au dessus de l unit r frig rante situ e derri re l appareil Assurez vous qu il reste un espace libre minimum de 4 pouc...

Page 12: ...et D Appliquez une solution bulles de savon du commerce non corrosive sur la buse du br leur Aucune bulle ne doit appara tre l orifice de la buse 6 La pr sence de bulles indique un d faut de fonction...

Page 13: ...n 2 B du thermostat sur la position 4 Enfoncez le bouton 3 C fond puis en le maintenant ainsi poussez plusieurs reprises le bouton D de l allumoir pi zo pour allumer le br leur L allumage du br leur p...

Page 14: ...sition m diane d s que la glace se sera form e Les aliments dans le compartiment inf rieur pourraient geler si le bouton restait sur la position de r glage MAX D givrage Le givre ne doit pas pouvoir s...

Page 15: ...sement peut provoquer une explosion avec des risques d accident mortel ou de graves blessures N B Du chromate de sodium est utilis comme protection contre la corrosion moins de 2 pour cent en poids du...

Page 16: ...la pression du GLP propane V rifier la pression du GLP propane et r gler de nouveau le r gulateur principal si la pression n est pas correcte La pres sion de service qui convient est de 11 pouces de...

Page 17: ...ange La liste suivante indique les pi ces habituellement utilis es et pouvant tre disponibles en cas de besoin aupr s de votre centre d entretien Dometic N de r f rence Description 200 74 19 21 7 Buse...

Page 18: ...s of this Warranty the Original Purchaser should contact their selling dealer If none is available you may call for the location of a service center at 1 800 544 4881 In Canada call 1 519 653 4390 Be...

Page 19: ...ty Registration Form an a check Mastercard Visa or Discover card number covering the charge for the DOMETICARE coverage Any cooling unit which is replaced will not be returned to the Original Purchase...

Page 20: ...Please Process At Once Name_ _____________________________ Address_ __________________________ City ST Zip_ _______________________ Please check here if new address TO THE INSTALLER PLEASE AFFIX THESE...

Reviews: