31
D+
connection and Solar Control connection
(
AES
only
)
D+ connection:
The D+ control connection must be connected to the respective vehicle
terminal (alternator signal while motor is running).
Solar control input (S+):
Connection only when using a solar system with a solar charging
controller with AES output.
The respective solar charging controllers are available from a specialized
dealer.
The “Solar” (S+) control connection must be connected to the respective
terminal of the solar charging controller (AES output).
Cable cross-sections
There are no particularly high current flows via the D+ and S+ connection;
therefore no particularly large cross-section is required for these connections
(approx. 1mm²).
Terminal strip DC
connections
(
MES and AES)
Retrofitting
Connections:
A = Ground heating element
DC
B = Plus heating element DC
C = Ground electronics
D = Plus electronics
D+ = alternator signal
S+ = AES-input-control signal
(solar charge regulator)
8.9.3
8.9.4
8.9.5
D
C
A
B
D
C
permanent DC-connection
12V DC
heating-connection
RETROFITTING
From the manual energy mode to the automatic energy mode
For all
MES appliances there is an additional possibility for retrofitting to an
RMT 7xx5 device with AES functions.
Please consult your nearest Dometic Customer Service or your specialist dealer
.