The gas connection to the appliance is effected by means of a suitable
coupling tube fitting L8, DIN 2353-ST, complying with EN 1949 (e. g. Ermeto).
The gas connection may only be carried out by a qualified personnel.
29
Following proper installation, a testing for leakage and a flame test must be car-
ried out by *qualified personnel in compliance with EN 1949 .
A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts who are able, by virtue of their training and knowledge,
to vouch for the correct implementation of the leakage test.
A
AT
TT
TE
EN
NT
TIIO
ON
N
20 Nm
max
15 Nm
max
Gas supply
oven
connection
gas supply
Gas burner
Refrigerator
Gas valve
Refrigerator
The refrigerator must be equipped with a gas cock
in the supply line to allow the supply to be disconnected.
Such a cut-out device must be readily accessible to the
user.
Gas pressure
Category I
3P(30)
I
3P(37)
I
3P(50)
I
3+
I
3B/P(50)
I
3B/P(30)
mbar 30
37
50
28-37
30-37
50
30