11
If gas faults occur the operating LED “C”
flashes
yellow
.
Remedies:
Set the energy selector switch “A” to position “OFF”.
1. Is there any gas in the gas bottle?
2. Is the gas bottle valve open?
3. Is the on-board shut-off valve open?
If point 1 to 3 is
ok proceed with point 4 .
4. Set the energy selector switch “A” to position “AUTO” again.
The ignition starts once more.
If after about 30 seconds the operating display (C) starts flashing
yellow
again, the gas fault has not been cleared (e.g. air in the gas pipe).
5. Briefly set the energy selector switch “A” to position “OFF” and back again to
position “AUTO”!
To remove air from the gas pipes, repeat this procedure 3-4 times.
If these actions do not help, please call an authorised Dometic Service
Centre.
Frame heating
Additional functions (RMT 7655, RMT 7855)
5.2.4
C
A
Gas faults
(
MES and AES)
Temperature setting display (D) with 4 LED to
indicate the selected temperature (MIN - MAX).
LED - dimmer (E) for adjusting the brightness of
the display-LED.
(only accessible when door opens)
D
E
Underneath the fascia is a knurled knob for
adjusting the brightness (see item E above).
All models are equipped with a frame heating
(12VDC/3,5W) around the freezer compartment. During
summer months with high temperatures and humidity the
metal frame may have water droplets forming. To evapo-
rate these droplets switch on the frame heating with
switch (A). The LED (B) indicates that the heating is on.
The frame heating will draw 12V DC power continuously.
Observe LED (B) when the engine is shut off while parking the vehicle.
Shut off the frame heating.
A
B
5.2.5