34
are several operating methods being used simultaneously?
have warm foodstuffs been stored in the cooler?
was a too large a quantity of food or drink stored at any one time? Food
and drink should be so stored as to allow free air circulation. Do not use
paper or plastic plates. Always keep containers for liquids sealed.
Indicate the type of defect, type of appliance, product number and serial
number (on the type plate at the back of the unit).
We accept responsibility for the perfect condition of the unit, the guarantee
being in accordance with our guarantee conditions.
18. Technical Data
Gas operation butane (propane)
Rated thermal loading:
112 W
(118 W)
Min. thermal loading:
89 W
(86 W)
Connected load, gas:
8,1g/h
(8,4 g/h)
Connection pressure:
28-30/37 mbar
Categorie:
I3+
Climat class:
'N'
Electric operation:
220V-240V (mains) 50 Hz:
75W
12V (car battery):
75W
24V (car battery):
65W
Capacity:
33 Ltr.
Refrigerant:
0,24 kg. NH
3
+ H
2
O
The refrigeration cycle has been checked for leaks.
The appliance does not contain any CFCs/HCFCs.
Sodium chromate is used for corrosion protection (less than 2 weight % of the
coolant).
This appliance complies with the following EEC directives:
LVD-Directive 73/23/EEC with amendment 90/683/EEC;
EMC-Directive 89/336/EEC;
Gas-Directive 90/396/EEC.