background image

30

To turn on

The  car  plug  fitted  to  the  connecting  cable  is  to  be  plugged  into  the

socket/cigar lighter (car plugs are not supplied with every model).
When  using  battery  operation,  the  cooling  performance  is  not

thermostatically regulated, i.e. knob (A) is ineffective.
When knob (A) is ineffective or if the temperature is unnecessarily too low:

Turn off unit

Pull out plug from socket.

8. Liquid gas operation

Do not use any additional form of energy (mains/battery). The unit must not

be connected to town or natural gas pipelines. It is only suitable for use with

propane/butane gas (e.g. Calor Gas, Camping Gaz, Caravangas, etc).
The specified gas-connection pressure is given in mbar on the type plate

(see  back  of  appliance).  It  is  important  that  a  non  adjustable  pressure-

regulator is used to reduce the pressure in the gas cylinder to the operating

pressure specified on the rating-plate, no other pressure may be used.

Needle valve operated gas control taps are NOT suitable for use with

this  appliance  and  must  not  be  used  as  a  substitute  for  a  pressure

regulator.

9. Connecting the cooling unit to the gas

cylinder

(The following instructions refer in the main to coolers manufactured for the

United Kingdom. For other countries please refer to your supplier).
Always connect in the following sequence:

GAS BOTTLE 

PRESSURE-REGULATOR 

APPLIANCE.

To connect the appliance to the pressure-regulator an  APPROVED GAS

TUBING should be used. This should be minimum in length - have an inside

dimension of 8mm and be marked BS3212/2/8.
The pressure-regulator must be compatible for Butane 11 in (28 mbar) or for

Propane (37 mbar).
To  connect  the  pressure-regulator  to  the  gas  bottle,  the  valve  of  the  gas

bottle must be closed. After connecting the  pressure regulator to the bottle

GB

Summary of Contents for RC1600

Page 1: ...207 5013 04 Type JCB 1 Gebrauchsanweisung Mode d emploi Instruzioni per l uso Operating instructions Gebruiksaanwijzing Instrucciones de manejo DE AT CH LU BE CH IT CH GB NL ES IE LU 0402...

Page 2: ...ate ventilation as a failure to do this will result in component failure and possible food loss refer to relevant instructions for unit installation under point 4 Before defrosting cleaning or mainten...

Page 3: ...ed This will result in a good energy saving cooling system 5 Cleaning Prior to initial use and later after defrosting or prior to a prolonged period out of operation clean the container and lid with l...

Page 4: ...correctly Connections should be firmly made after all conductor strands are entered into the terminal posts When preparing the cable ends take care not to damage the outer sheath or the insulation sur...

Page 5: ...kwise to position 0 a slight resistance will be felt just before this position Pull out mains plug 7 D C operation Do not use any additional form of energy mains gas A safety fuse must be installed in...

Page 6: ...to reduce the pressure in the gas cylinder to the operating pressure specified on the rating plate no other pressure may be used Needle valve operated gas control taps are NOT suitable for use with t...

Page 7: ...e burner every time after connection turn on the gas at the bottle and check the gas connections for leaks by applying a soap and water solution over them and watching for bubbles which would indicate...

Page 8: ...sition 13 Food and drink storage Foodstuffs and drinks should always be sealed when stored in the cooling unit Thus changes in taste and smell are avoided Food and drink should be so placed in the coo...

Page 9: ...lace the gas filter remove the filter from the duct and replace it with a new one Any other maintenance and repair works especially those relating to the cooling aggregate and the gas burner system ma...

Page 10: ...in accordance with our guarantee conditions 18 Technical Data Gas operation butane propane Rated thermal loading 112 W 118 W Min thermal loading 89 W 86 W Connected load gas 8 1g h 8 4 g h Connection...

Page 11: ...51 Fig 1...

Page 12: ...52 Fig 3 Fig 2...

Page 13: ...53 Fig 5 Fig 4 joint guarnizione afdichting junta joints guarnizione afdichtingen junta...

Page 14: ...54...

Page 15: ...55...

Page 16: ...Printed by Xerox Hungary Ltd Rev 2003 12 17...

Reviews: