4. Roof-vented installation: Align the damper/duct connector
with the vent on top of the microwave oven. Damper should
be on top of tab. Use two tapping screws (bright-colored) to
attach damper/duct connector to the microwave oven. See
Figure 32.
NOTE: Damper/duct connector must be attached to
microwave oven after microwave oven is installed.
5. Roof venting installation: Install ductwork through the vent
opening in the upper cabinet. Complete the venting system
through the roof according to the method needed. See
Figure 33. See PREPARE THE VENTING SYSTEM,
STEP 2 on the page 8. Use caulking to seal the exterior
roof opening around the exhaust cap.
See Figure 6 on page 8.
6. Use the power supply cord clamp to bundle the power
supply cord. Install the power supply cord clamp, using a
screw as shown in Figure 33, to inside of the cabinet.
7. Grasp filter screen with one hand holding the ring and the
other hand holding the opposite end. Insert the end of the
filter screen without ring into the opening and slide towards
the side of the microwave oven. Insert ring end of filter
screen into the opening and slide entire screen towards the
center of the microwave until screen is securely in position.
Repeat for other filter screen. See Figure 34.
8. Plug in the power supply cord.
9. Read your Owner’s Manual, then check the operation of
your microwave oven.