1. Remove the templates from upper cabinet and wall.
NOTE: If you are venting the oven through the wall,
be sure you align the damper/connector on the
rear of the mounting plate with the 3 1/4"x10" duct.
Be sure the damper moves freely.
See Figure 24.
2. Prepare the toggle bolts by putting the bolts through
the corner holes and attaching a spring toggle head to the
end of each toggle bolt as shown in Figure 25.
3. Place the mounting plate against the wall and match the
screw holes. See Figure 26.
NOTE: Be sure to leave at least one wall-thickness of
space between the head of the toggle bolt
and the spring toggle head so that the spring
toggle can open on the inside of the wall,
as shown in Figure 27.
You may have to pull out slightly on the
bracket to put tension on the toggles.
4. Locate the stud holes (3/16") and insert the lag screws
through the mounting plate and into the holes.
See Figure 28.
5. Insert the toggle bolts through the drywall holes (3/4").
Tighten the toggle bolts.
6. Insert a flat-blade screwdriver through the rod retainer
screw clearance holes and into the mounting plate nuts in
those holes. See Figure A. Move the screwdriver around
to be sure the nuts move freely, as shown in Figure A. If
the nuts do not move freely, the mounting plate may be
too close to the wall. Loosen the toggle bolts and lag
screws and adjust the mounting plate.
STEP 5:
INSTALL THE MOUNTING PLATE
Figure 24
Figure 23
Figure 26
Figure 25
mounting plate
Damper must be on top of
tab for proper venting.
toggle bolt
mounting plate
spring
toggle head
support tabs
Figure 27
wall
mounting plate
toggle bolt
spring
toggle head
Figure 28
lag screw
mounting pate
– 14 –
Figure A
rear
mounting
plate