ELECTRICAL SHOCK HAZARD!
UNPLUG UNIT BEFORE WORKING ON IT.
• DO NOT PULL OR STRETCH THE BLOWER WIRING! Pulling and stretching the blower wiring could
result in electrical shock.
Remove the two vent grille mounting screws and tip the vent
grille forward, then lift it out. See Figure 10.
Loosen the two rod retainer screws behind the vent grille.
See Figure 10-1, remove the wall mounting plate from the
back of the oven and set aside.
WALL-VENTED INSTALLATION:
Go to STEP 4 on page 12.
ROOF-VENTED INSTALLATION:
1. Remove one blower unit mounting screw and two blower
plate screws. Remove the blower plate from cabinet.
See Figure 11.
2. Disconnect the power plug from the oven.
3. Carefully lift the blower unit out of the microwave oven.
4. Reassemble the blower wire.
The blower wire must be replaced under the supporter.
See Figure 12.
5. Rotate the unit so that the exhaust ports face the upper of
the cabinet.See Figure 13.
6. Place blower unit upper into cabinet. Check that the
exhaust ports face the upper of the cabinet.
See Figure 14.
7. Connect the power plug.
8. Use side cutters or tin snips to cut and remove knockouts
from blower plate. Discard knockouts.
Be careful not to distort the plate. See Figure 15, page 11.
9. Reattach the blower plate to cabinet so the exhaust ports
and blower plate opening are aligned. Attach with one
blower unit mounting screw and then two blower plate
mounting screws. See Figure 16, page 11.
STEP 3:
PREPARE THE VENTING BLOWER
blower plate
mounting screws
blower unit
mounting screw
blower
unit
Figure 10
Figure 10-1
Figure 11
Figure 12
Supporter
blower
wire
back plate
Figure 14
Figure 13
blower
unit
exhaust
ports
exhaust
ports
W A R N I N G
– 10 –
Summary of Contents for DOTRM13B
Page 17: ...M ME EM MO O...
Page 18: ...PRINTED IN KOREA...