background image

AVOID ELECTRICAL SHOCK! THIS APPLIANCE MUST BE GROUNDED!

1. Locate the grounded electric outlet for this oven in the

cabinet above the oven, as shown in Figure 4.

NOTE: The outlet should be on a circuit dedicated to the

microwave oven (120V, 60Hz., AC only) with a 
15 or 20A fused electrical supply.

IMPORTANT: If you do not have the proper wall outlet, you

MUST have one installed by a qualified
electrician.

2. You will cut the power-supply-cord hole (shown in 

Figure 4) later when you prepare the wall and upper cabinet
in Step 4.

NOTE: Do not use an extension cord.

Keep the power cord dry and do not pinch or crush it. 

Improper grounding could result in 

electric shock or other personal injury.

• DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY

CORD GROUNDING PRONG!  
This appliance MUST be grounded!

STEP 1:     PREPARE THE   

ELECTRICAL CONNECTIONS

Grounded Outlet
( Inside Cabinet )

Upper
Cabinet

Power-Supply-Cord Hole

Figure 4

W A R N I N G

W A R N I N G

– 7 –

Summary of Contents for DOTRM13B

Page 1: ...MODEL NO DOTRM13B DOTRM13W Please read and save these installation instructions P N 3828W5U0042 OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS...

Page 2: ...hock Before you drill into the wall note where electrical outlets are and where electrical wires might be concealed behind the wall YOU COULD GET AN ELECTRIC SHOCK if you contact electrical wires with...

Page 3: ...VE THESE INSTRUCTIONS FOR THE LOCAL ELECTRICAL INSPECTOR S USE DO NOT EXPOSE YOURSELF TO EXCESSIVE MICROWAVE ENERGY DO NOT try to operate the microwave oven with the door open DO NOT tamper with or de...

Page 4: ...dows doors and strong heating vents BE SURE you have enough space See Figure 4 below for minimum vertical and horizontal clearance If you do not mount the oven as instructed you risk personal injury a...

Page 5: ...must be assembled as shown One power cord clamp and One dark colored mounting screw to hold the power cord Actual Size Two self tapping screws Actual Size for attaching the damper duct connector Four...

Page 6: ...must have a back draft damper Shown on page 5 PARTS TOOLS MATERIALS Clear tape for taping the templates to the wall Stud finder or thin nail Saber saw for cutting vent holes for roof or wall venting K...

Page 7: ...by a qualified electrician 2 You will cut the power supply cord hole shown in Figure 4 later when you prepare the wall and upper cabinet in Step 4 NOTE Do not use an extension cord Keep the power cor...

Page 8: ...thod roof or wall venting be sure there is enough clearance within the wall for the exhaust duct REMEMBER AS YOU INSTALL THE VENTING Keep the length of the ductwork and the number of elbows to a minim...

Page 9: ...are the standard fittings and their equivalent length in feet To calculate the equivalent length of each ductpiece used see the examples below STEP 2 PREPARE THE VENTING SYSYTEM Figure 9 1 4 5 6 7 2 3...

Page 10: ...mble the blower wire The blower wire must be replaced under the supporter See Figure 12 5 Rotate the unit so that the exhaust ports face the upper of the cabinet See Figure 13 6 Place blower unit uppe...

Page 11: ...r unit back into microwave oven 5 Reattach blower plate to microwave oven Attach with one blower unit mounting screw and then two blower plate mounting screws See Figure 19 STEP 3 PREPARE THE VENTING...

Page 12: ...OVEN IF YOU CANNOT FIND A WALL STUD 3 Line up the plumb line on the wall with the center line on the wall template NOTE Be sure the minimum width is 30 inches and the distance from the top of the wall...

Page 13: ...pector There must be at least one stud in those areas 3 Cut or drill a 2 diameter hole at the area marked M Power supply cord hole on the upper cabinet template If the upper cabinet is metal you will...

Page 14: ...the bracket to put tension on the toggles 4 Locate the stud holes 3 16 and insert the lag screws through the mounting plate and into the holes See Figure 28 5 Insert the toggle bolts through the drywa...

Page 15: ...e upper cabinet or cabinet frame 3 Use a flat blade screwdriver to push in and thread the rod retainer screws clockwise until they are tight in the mounting plate nuts as shown in Figure 30 Try wiggli...

Page 16: ...cap See Figure 6 on page 8 6 Use the power supply cord clamp to bundle the power supply cord Install the power supply cord clamp using a screw as shown in Figure 33 to inside of the cabinet 7 Grasp f...