EN
MCA1215 – MCA2440
Connecting the device
25
➤
Use the DIP switches (fig.
a
page 7) to set the required functions and values:
–
To set the switchover voltage:
–
To set the retention voltage:
–
To set the power mode:
–
Enabling the control for external devices (such as MPC01, does not apply to
MCA-RC1):
–
To activate sleep mode:
Switch 1
Switch 3
Switchover voltage
ON
OFF
14.4 V / 28.8 V
OFF
OFF
14.7 V / 29.4 V
Switch 2
Switch 3
Retention voltage
ON
OFF
13.5 V / 27.0 V
OFF
OFF
13.8 V / 27.6 V
Switch 1
Switch 2
Switch 3
Constant voltage
MCA12..
MCA24..
OFF
OFF
ON
13.2 V 26.4 V
OFF
ON
ON
13.8 V
27.6 V
ON
OFF
ON
14.4 V
28.8 V
Switch 1
Switch 2
Switch 3
ON
ON
ON
Switch 4
ON
MCA1215-2440--IO-16s.book Seite 25 Mittwoch, 25. Juli 2018 2:39 14