EN
Technical data
MCA1215 – MCA2440
32
Protective devices
Input data
MCA12xx, MCA24xx
Output side short circuit:
Current is reduced to 25 % of the
maximum current
Overvoltage:
16 V
Battery charger over temperature:
100 °C ± 5 °C (measured internally)
Battery over temperature:
52 °C ± 5 °C (with battery sensor)
MCA1215
MCA1225
MCA1235
MCA1250
MCA1280
Rated input voltage:
90 – 260 V
w
Output factor correction:
> 97% (full load)
Input frequency:
50 Hz – 60 Hz
Efficiency at 230 V
w
:
87%
Leakage current:
< 1 mA at 240 V
w
Input current at 100 V
w
:
2.5 A 4.1 A
6.2 A
8.24 A
13.3 A
Input current at 240 V
w
:
1.07 A 1.8 A
2.8 A
3.6 A
5.4 A
MCA2415 MCA2425 MCA2440
Rated input voltage:
90 – 260 V
w
Output factor correction:
> 97% (full load)
Input frequency:
50 Hz – 60 Hz
Efficiency at 230 V
w
:
90 %
Leakage current:
< 1 mA at 240 V
w
Input current at 100 V
w
:
4.2 A
8.3 A
13.3 A
Input current at 240 V
w
:
1.7 A
3.6 A
5.4 A
MCA1215-2440--IO-16s.book Seite 32 Mittwoch, 25. Juli 2018 2:39 14