EN
MCA1215 – MCA2440
Technical data
31
14
Technical data
General technical data
MCA12xx, MCA24xx
Battery types:
Lead-acid, gel, AGM, Li-Ion
Heat dissipation:
Fan
Charge mode:
5-level
Maximum ambient temperature:
–20 °C – +50 °C
Storage temperature:
–40 °C – +85 °C
Air humidity:
20 – 90 %
Temperature coefficient:
± 0.03 %/°C (0 – 50 °C)
Temperature compensation (MCA12xx)
Temperature compensation (MCA24xx):
–20 mV/°C (battery sensor)
–40 mV/°C (battery sensor)
Vibration:
10 – 500 Hz
2 g for 10 min/cycle within 60 minutes for X, Y and
Z axis
Voltage insulation:
I/P – O/P: 4 kV
w
I/P – FG: 1.7 kV
w
O/P – FG: 0.7 kV
w
Insulation resistance:
I/P – O/P: 100 M
Ω
/500 V
g
Alarm signal:
via relay contact
Communication:
via LIN-BUS
Sleep mode (noise-reduced mode):
via remote control (accessory) or DIP switch
Remote control (accessory):
On/off switch, three-colour LED, sleep mode
option
Testing/certification:
MCA1215-2440--IO-16s.book Seite 31 Mittwoch, 25. Juli 2018 2:39 14