EN
Installing the device
SMP439-11 (7LA.915.681)
12
•
Do
not
install the device
–
In wet or damp environments
–
In dusty environments
–
In the vicinity of combustible materials
–
In areas where there is a danger of explosions.
•
The place of installation must be well ventilated. A ventilation system must be
available for installations in small, enclosed spaces.
•
The air inlet on both short sides of the device must remain clear.
•
For ambient temperatures higher than 40 °C (such as in engine or heating com-
partments, or direct sunlight), the heat from the device under load can lead to
reduced output.
•
The device must be installed on a level and sufficiently sturdy surface.
•
When installing the device above batteries, ensure that the vent hoses are con-
nected tight and leak-proof to the batteries to avoid damage to the device
caused by escaping corrosive sulfur fumes.
A
5.2
Connecting the device
Connecting the battery
Observe the following instructions when connecting the battery:
!
•
Ensure that the battery terminals are clean when connecting them.
•
Ensure that the plug connector is fitted securely.
•
Select a connection cable with a sufficient cross-section (suitable for 15 A).
•
Use both the positive and both the negative connections to connect the battery.
•
Lay the cables in accordance with VDE 100 (Germany).
•
Use the following cable colors:
–
Red: positive connection
–
Black: negative connection
NOTICE!
Before drilling any holes, make sure that no electrical cables or other
parts of the vehicle can be damaged by drilling, sawing and filing.
CAUTION!
•
Avoid coming into contact with the battery fluid.
•
Batteries with a cell short circuit may not be charged, as explosive
gases may form due to overheating of the battery.