AZ motor
Edition 4
Instructions for bearings replacement
49
Step 29: Connecting motor cable to motor controller
You will need a TORX T20 screwdriver (a) and a small flat screwdriver (g) for this step.
RISK OF ELECTRIC SHOCK.
Before connecting the motor cable to motor controller ensure that
motor controller is disconnected by the mains voltage and that
motor does not rotate.
The fan, mounted on the motor shaft, could rotate due to different
influences in the air channel. The rotation of the fan causes the
rotation of the motor. In such case the motor generates electrical
voltage. And a touch of the non-insulated wires of the connection
cable can lead to serious injuries.
Connect the motor cable to motor controller. Be careful that signs on controller match signs
on cable. Connect also the cable screen. Place the cover on motor controller.
Step 30: Installing the wheel
You will need a tool for fan wheel installation (s) and suitable wrench for this step.
Too high assembly force can damage motor bearings and wave
spring washer which can lead into shorter bearings life time.
Axial force for fan assembly must not exceed permissible force
defined in table 11.
Table 11. Permissible force for wheel installation
Motor type
Max. force for
fan assembly [N]
746.3.xxx (AZ 84)
80
747.3.xxx (AZ 108)
100
748.3.xxx (AZ 150)
200
749.3.xxx (AZ 220)
300