7.2 Checks before each setting in motion/ daily checkings
Each time you set the unit in motion, check if the network or better the supply line
complies with the regulations in law.
Compare the voltage indicated on the motor plate with that supplied by the network.
Check and lubricate periodically all the moving parts(about each 50 operating hours).
Remove old and spent lubricant.
Danger of explosion due to biogas emissions!
Check
daily
if the rubber parts of the expansion joint are damaged or torn.
Hazard of damages to the mixer or injuries to persons!
Check
daily
the stability of the fixing bolts put on the direction adjusting device and on
the hydraulic jack.
Check if they are damaged or torn.
In case of damages or unsuitable fixing, the mixer has to be stopped immediately to
remove the failure found out.
All bolts and nuts have to be fixed firmly as indicated in the table in
Chapter 8
and
then
daily
checked. All corresponding operations have to be documented.
1) Drive line oil level
2) Drive line oil vent/ inlet
3) Gearbox oil level
4) Gearbox oil vent/level