20
7
SETTING IN MOTION
7.1 Check at the first setting in motion
Check the motor rotation direction: the motor has to turn
clockwise
as indicated by the
arrow on the motor.
Start the motor for any seconds to check if the motor cooling fan turn rightwards.
The mixing propeller has to turn clockwise as well.
If the propeller is not clearly visible, it is necessary to check the rotation direction of the
mixing propeller of the activation motor.
Hazard of damages to the mixer and injuries to persons in case of
employment in the opposite rotation direction to that indicated!
According to the electric polarization of the 400V connection, the motor rotation could
be wrong!
Check if the mixer is correctly fixed on the foreseen installation surface.
Check if all bolts set on the mixer are correctly fastened.
Both moving parts of the hydraulic direction adjusting device and the bearing bushes of
the fixing bolts have to be lubricated.
Set the unit in motion only after having checked the oil level in the drive line, in the gearbox
and in the hand pump for the hydraulic regulation.
The correct oil quantity is the following:
-
18 litres of Shell Tivela oil (or equivalent) for the gearbox;
-
42 litres of SAE80 – W90 for the drive line;
-
3 litres of Nuto 68 oil (or equivalent) for the hand pump.
In order to check oil, act as follows:
-
unscrew inlet and vent caps;
-
After having filled the machine up with oil, wait at least 3 hours before setting the unit in
motion.
-
Screw caps again.
-
Check oil level periodically: it has never to be beyond the indicated level.
N.B. During filling up and check, the drive pipe, has to be as vertical as possible.