13
3.
Nesting Mode On/Off.
When the optional Nesting
Fixture is supplied and "NESTING MODE "ON",
there is vise open time delays and "out of stock"
lengths change.
•
See the
"ACCESSORIES"
section of this manual
for information on use of the optional Nesting Vise
Fixture.
4.
Cycle Mode Home Front/Rear.
This key toggles
between "HOME REAR" and "HOME FRONT" and
is used to select the position the index vise during
"AUTO MODE" cycle.
•
"HOME REAR" is the shortest cycle time and is
preferred for most operations when not using the
Nesting Fixture and/or Variable Vise Pressure
options.
•
"HOME FRONT" is preferred for most operations
when using the Nesting Fixture and/or Variable
Vise Pressure options. It allows the use of both
vises to provide extra clamping (one vise is always
clamped).
5.
Job Mode Single Job/Run List.
The operator
selects the type of job to run, a "SINGLE JOB"
in which the operator goes to the
VIEW
Screen
and enters the data for "CUT LENGTH and
QUANTITY.
•
"RUN LIST" allows multiple jobs to be programmed
into a library. The operator must press the "JOBS"
key to access the library.
• See
JOBS
Screen later in this manual to create a
library of jobs.
6.
Units.
This key allows the operator to select between
inches or millimeters (mm) for measurement data.
When switching from one to another, the data is
converted to the new measurement mode.
7.
Laser (Optional).
Press the key to turn the optional
laser "OFF" and "ON". The key will highlight when
it's on.
•
See the
"ACCESSORIES"
section of this manual
for information on use of the optional Laser Line.
8.
Coolant Off.
This key turns off both the Flood
Coolant system and the optional Mist Lubricator
system.
9.
Coolant On With Band.
Press this key for the Flood
Coolant to flow through the entire system while the
saw band is running.
This is the recommended
setting.
10.
Coolant On.
This key operates the coolant without
the band drive motor being on and is used mainly
for the use of the flushing hose.
11.
Mist Coolant On W/Band (Optional).
Pressing
this key activiates the optional Mist Lubricator
solenoid.
12.
Worklight (Optional).
Press the key turns the
optional Worklight "OFF" and "ON". The key will
highlight when it's on.
13.
Band Load %.
This displays the percentage of the
band drive motor amperage being used.
14.
Fault Code.
This displays a code when there is a
fault in the VFD module. Refer to the VFD manual
for more information.
15.
Band VFD
Fault Reset.
When there is a fault in
the VFD module, pressing this key will reset the
module and operation will be allowed to continue.
16.
Band Hours.
This displays an accumulative total
of hours that the band drive motor have been
running.
17.
Index Vise Clamped Delay.
Press this key and
the keypad will appear. Enter a time in seconds
allotted for the index vise jaws to clamp before
indexer movement is allowed and then press
OK
.
18.
Front Vise Clamped Delay.
Press this key and
the keypad will appear. Enter a time in seconds
allotted for the front vise jaws to clamp before indexer
movement is allowed and then press
OK
.
19.
Machine Hours.
This displays an accumulative total
of hours that the hydraulics have been running.
OPERATOR WORKSTATION (Continued....)
Summary of Contents for 500SNC
Page 1: ...Instruction Manual 500SNC Serial No 592 13178 to Band Sawing Machine ...
Page 6: ...2 MACHINE DIMENSIONS Continued TOP VIEW INCHES 03 MILLIMETERS 1 mm ...
Page 7: ...3 MACHINE DIMENSIONS Continued FRONT VIEW INCHES 03 MILLIMETERS 1 mm ...
Page 8: ...4 MACHINE FEATURES FRONT VIEW ...
Page 9: ...5 REAR VIEW MACHINE FEATURES Continued ...
Page 10: ...6 SIDE VIEW MACHINE FEATURES Continued ...