background image

 

DMX-LED-Dimmer X9

 

15 

 

Dimensions 

 

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

All details in mm 

Summary of Contents for DMX-LED-Dimmer X9

Page 1: ...DMX LED DIMMER X9 User Manual...

Page 2: ...is 100 dimmbar The connected LEDs are dimmed from 0 up to 100 via PWM For voltages from 12V up to 24V The DMX LED dimmer X9 works with supply voltages from 12V up to 24V The LED voltage can vary per o...

Page 3: ...nnels DMX Fail Hold 0 100 Output 9 PWM signals 8 bit resolution each common power supply Output current max 10A each output in sum 90A with all connected GND connections Output power 9x 120W 12V 9x 24...

Page 4: ...LED Stripe 12V POWER 12V GND V GND OUT1 GND OUT2 GND OUT3 GND OUT4 GND OUT5 GND OUT6 RGB LED Stripe 12V RGB LED Stripe 12V V DMX DMX GND ADDRESS GND GND GND OUT7 OUT8 OUT9 DMX IN DMX OUT Must be conn...

Page 5: ...V POWER 12V GND V GND OUT1 GND OUT2 GND OUT3 GND OUT4 GND OUT5 GND OUT6 RGB LED Stripe 24V RGB LED Stripe 12V V DMX DMX GND ADDRESS GND GND GND OUT7 OUT8 OUT9 DMX IN DMX OUT POWER 12V POWER 24V POWER...

Page 6: ...r X9 RGB LED Stripe 12V POWER 12V GND V GND OUT1 GND OUT2 GND OUT3 GND OUT4 GND OUT5 GND OUT6 LED Stripe WEI 12V LED Stripe WEI 12V V DMX DMX GND ADDRESS GND GND GND OUT7 OUT8 OUT9 DMX IN DMX OUT Must...

Page 7: ...8 9 10 LED Display Codes The integrated LED is a Multi functional display In the normal DMX mode the LED lights up nonstop In this case the device is working Also the LED signalled the operation stat...

Page 8: ...able with the Jumper ALL ON All outputs switched OFF 100 ALL OFF All outputs switched ON 0 HOLD Last value is HOLD Or RDM settings are used After switching the power off the hold values will be not re...

Page 9: ...installations the cable cross section should be large at most to keep a voltage drop low as possible The cable cross section should be even larger as the distance increases and the load increases The...

Page 10: ...espective all DMX values for 5 minutes to the value of 0 the controlling output will be shut down So the dissipation for the power supply which will not be needed for a longer time can be avoided Inst...

Page 11: ...rograms about the counters 1 2 and 3 The following colour changes are selectable Colour change 1 R OFF ON 1 2 3 4 5 6 7 8 9 10 G B Colour change 2 R OFF ON 1 2 3 4 5 6 7 8 9 10 G B Colour change 3 R O...

Page 12: ...witches is always prior This device supports the following RDM commands Parameter ID Discovery Command SET Command GET Command ANSI PID DISC_UNIQUE_BRANCH E1 20 DISC_MUTE E1 20 DISC_UN_MUTE E1 20 DEVI...

Page 13: ...X LED Dimmer X9 13 Manufacturer depending RDM control commands SERIAL_NUMBER PID 0xD400 Outputs a text description ASCII Text of the device serial number GET Send PDL 0 Receive PDL 21 21 Byte ASCII Te...

Page 14: ...power supply Set DIP switch 1 up to 10 to ON Turn on device connect power supply The LED lights up 20x during ca 3 seconds While the LED lights up set DIP switch 10 to OFF Now the Factory Reset is ex...

Page 15: ...DMX LED Dimmer X9 15 Dimensions All details in mm...

Page 16: ...DMX LED Dimmer X9 16 Accessories Housing for DIN Rail Mounting DIN Rail housing 1050...

Page 17: ...the EMC directive 2014 30 EU is necessary Disposal Electronical and electronic products must not be disposed in domestic waste Dispose the product at the end of its service life in accordance with app...

Page 18: ...e board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it...

Page 19: ...ems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason I see myself compelled to poi...