ArtNet Player X16+
22
Digital Inputs
The 8 digital inputs are designed for operation by remote pushbuttons. The inputs are
operated by a switching contact against GND:
IN1
IN2
IN3
IN4
GND
IN5
IN6
IN7
IN8
The inputs are not potential-free.
The function of the selected input can be set via the web configuration:
P
Switch to the next program. After the last program a rollover occurs to the first
program.
Program -
Switch to the previous program.
After the first, there is a rollover to the last program.