XTLplus International Series Installation and Programming Guide
Digital Monitoring Products
43
APPENDIX
This section provides additional zone and system information.
Status List
The Status List is the current status of the system or records of recent system events that display on alphanumeric
keypads. For example, in Home/Away systems you may see the display
SYSTEM READY
.
If an event were to occur on the system, such as an AC failure, the keypad would also display the
AC POWER -TRBL
message. This is a system event that is placed into the Status List to alert the user to a problem with the system.
Some Status List items remain in the display until manually cleared and some are cleared automatically when the
condition returns to normal. Below is a list of status and event displays the keypad can show in the Status List:
• Fire, Carbon Monoxide, and Supervisory zone alarms: Yes, by Sensor Reset.
• Fire, Carbon Monoxide, and Supervisory zone troubles: No, clears when zone restores
• Burglary zone alarms: No, clears at disarming.
• All other zone alarms: No, clears when zone restores
• Zone monitor displays: No, clears after approximately 8 minutes
• Day zone alerts: No, clears after approximately 8 minutes
• System monitor trouble: No, clears when condition restores (AC and battery trouble)
• Armed status display: No (System On)
• Disarmed status displays: No (System Ready, System Not Ready)
• Remote keypad messages: No (Sent to the keypad by your office or central station)
Each item in the list is displayed for four seconds. When there are multiple items in the list, you can use
CMD
or Back
Arrow key to scroll forward or back through the items.
Transmission Delay
You can set Abort Reports to
YES
if Opening and Closing reports are not being sent.
If the area where the alarm occurred is disarmed during the Transmit Delay time, only an Abort Report (S45) message
is sent to the receiver. If the area where the alarm occurred is disarmed after the alarm message is sent to the receiver
but before the Bell Cutoff time expires, even if the alarm was silenced, an Alarm Cancelled (S49) message is sent. The
Alarm Cancelled report cannot be disabled.
False Alarm Reduction
System Recently Armed report
The System Recently Armed report (S78) is sent when a burglary zone goes into alarm within two minutes of the
system being armed.
Diagnostics Function
The XTLplusINT panel contains a Diagnostics function that allows you to test the integrity of the network
communication, integrity of the cellular communication and cellular signal communication of the 265LTE-INT Series to
the nearest tower for the cellular carrier. The Diagnostics function also displays the panel settings. To use Diagnostics,
reset the panel, enter the Diagnostics code 2313 (DIAG), and press
CMD
.
MAC Address
Short for Media Access Control address. This hardware address uniquely identifies each network node. Not to be
confused with an IP address, which is assignable. In the Diagnostics function, the MAC address is the panel on-board
network hardware address. Press any select area to display the panel MAC address. Press
CMD
to view the next
option.
Serial Number
This number is the network communicator serial number. Reference this number for communicator date-of-
manufacture, hardware version, etc. Press any select area to display the Serial Number. Press
CMD
to view the next
option.
Panel Settings
Pressing a select area displays the MAC Address, Serial Number, Frequency Offset, Panel Model, and Firmware Version.