XTLplus International Series Installation and Programming Guide
Digital Monitoring Products
31
OUTPUT SETUP
Output Setup
This section allows you to program and name wireless outputs into the panel.
Output Number
Enter an output number. Select from the following output numbers:
• 51 to 54 — Slow response time* wireless outputs (activate within 15 seconds)
• 61 to 64 — Fast response time* wireless outputs (activate within 1 second)
Addresses 51 to 54 and 61 to 64 are available for wireless outputs or wireless key fob
zones and can only be assigned to one device.
* The response time of a wireless output is the time it takes for a wireless output to
activate once the panel event occurs. You determine whether a wireless output is a slow
or fast response based on the output number assigned. A slow response output number
extends battery life, but response time may be up to 15 seconds. A fast response output
number responds within 1 second, but reduces battery life. Refer to the specific wireless
output installation guide to determine battery life.
Output Name
This section allows you to define a 16 character alphanumeric name for any wireless
output.
An output that is not part of the system must be marked * UNUSED *. To mark an output
unused, press any select area to display the default name, then press
CMD
. The pro-
grammer auto matically pro grams the name as * UNUSED *.
Serial Number
Enter the eight-digit serial number found on the wireless device.
Already in Use displays when the serial number is already programmed for another
output or zone. The programmed output or zone number displays.
Supervision Time
Press any top row key to select the supervision time required for the wireless output.
Press
CMD
to accept the default time. Default is
240 minutes
.
Select the required number of minutes. The transmitter must check in at least once
during this time or a missing condition is indicated for that zone. 1100INT Series
transmitters automatically check in based on the supervision time selected for the
wireless zone, no additional programming is needed. Zero (0) indicates an unsupervised
transmitter.
The 3 minute supervision time is only available if using an 1135INT Wireless Siren.
When the panel is reset, a receiver is installed or powered down and powered up, or
programming is complete, the supervision timer restarts for all wireless outputs.
Trip with Panel Bell Option
This option displays when the wireless device is an 1135INT wireless siren. Select YES to
have the 1135INT wireless siren follow the panel bell output. Default is
YES
.
OUTPUT SETUP
OUTPUT NUMBER
OUTPUT NAME
SERIAL#: XXXXXXXX
SUPERVSN TIME: 240
0 3 60
240
TRIP WITH PANEL
BELL NO
YES