XTLplus International Series Installation and Programming Guide
Digital Monitoring Products
23
SYSTEM OPTIONS
System Options
This section allows you to select system wide parameters used in the operation of the
XTLplusINT panel. A description of each System Option follows:
System
This configures the panel as either a Home/Away system (Perimeter, Interior, and
Bedrooms), an All/Perimeter system (Perimeter/Interior), or a six Area system. Zones
must be assigned to Bedrooms for the area to be active.
Wireless zones in an Area or All/Perimeter system resound the trouble buzzer every four
hours when zone trouble or low battery is displayed.
Closing Code
When YES is selected, a code number is required for system arming. If NO is selected, a
code number is not required for system arming. Default is
NO
.
Closing Check
Select YES to enable the panel to verify that all areas have been armed after a schedule
expires. If the Closing Check finds any areas disarmed past the scheduled time, all
keypads emit a steady beep and display CLOSING TIME!. The user must extend the
schedule or arm the system within 10 minutes or a Late to Close message is sent to the
central station. Default is
NO
.
Entry Delay
Enter the entry delay time for all exit type zones programmed to use Entry Delay 1.
When an armed Exit type zone is faulted, the keypad prewarn tone begins sounding.
ENTER CODE: - and the name of the zone causing the Entry Delay displays on all
keypads.
When the first digit of a code is entered, the prewarn tone stops at the keypad. If, within
five seconds, a valid user code is not entered or an invalid user code is entered, the
prewarn tone begins sounding again. Fifteen seconds must elapse before entering a
digit silences the prewarn tone again.
The area must be disarmed before the entry delay expires or an alarm is detected. All
Burglary type zones in all areas are delayed along with the Exit zone.
Entry delay times can be from 30 to 250 seconds. Repeat the above for Entry Delay 2 if
it is being used. Default is
30 seconds
for Entry Delay 1.
Specific Exit Error operation is based on the Entry Delay used (1 or 2) with an EX type
zone. See Exit Delay.
Exit Delay
Enter the Exit Delay time for all Exit type zones. When the exit delay time
starts,
all activity on exit and burglary zones is ig nored until the exit delay expires. The keypad
displays the Exit Delay time countdown and annunciates the Exit Delay tone at 8 second
intervals until the last 10 seconds when annunciation is at 3 second intervals. The exit
de lay can be from 45 to 250 sec onds. Default is
60 seconds
. During Exit Delay, if an exit
zone trips, then restores, and trips again, the Exit Delay timer restarts. This restart can
occur only once.
Exit Error Operation: At arming, when an entry/exit zone (EX) is faulted at the end of the
exit delay then one of two sequences occur:
For Entry Delay 1 EX type zones:
• The bell sounds for the length of time set in Bell Cutoff programming
• The Entry Delay operation starts, requiring code entry to disarm
• If not disarmed, a zone alarm and an Exit Error are sent to the receiver
For Entry Delay 2 EX type zones:
SYSTEM OPTIONS
SYSTEM: HOME/AWAY
AREA A/P
H/A
CLS CODE
NO
YES
CLS CHK
NO
YES
ENTRY DLY 1: 30
ENTRY DLY 2: 60
EXIT DELAY:
60