XTLplus International Series Installation and Programming Guide
Digital Monitoring Products
21
SYSTEM REPORTS
System Reports
This function allows you to select the reports the XTLplusINT sends to the receiver.
Opening/Closing Reports
NO - No Opening/Closing Reports are sent.
YES - Sends Opening/Closing Reports for each programmed area.
Abort Reports
YES allows the panel to send an Alarm Abort Report to the receiver any time an area is
disarmed during Transmit Delay before an alarm report is sent and the Bell Cutoff Time
has not expired. See the Bell Cutoff section. The area must be disarmed and no zones
that were in alarm can still be armed.
YES also allows a Bell Silenced Report to be sent if the alarm bell is silenced with a valid
user code during an alarm. Default is
NO
.
Alarm Cancel or Verify Reports are sent if the alarm is canceled or verified after being
sent to the alarm receiver, if the Bell Cutoff timer has not expired. The Abort Reports
option does not affect Cancel or Verify reports.
The panel will not send Abort reports for Fire zones, or Supervisory-type zones.
Zone Restoral Reports
This option allows you to specify whether the panel sends zone restoral reports and
when they will be sent.
NO - Restoral reports are not sent by the panel.
YES - The panel always sends zone restoral reports at the time the zone restores from
an alarm or trouble condition.
DISARM - The panel sends zone restoral reports when a zone that has restored from an
alarm or trouble is disarmed. Twenty-four hour zones send restorals immediately.
Bypass Reports
YES allows the panel to send all zone bypass, reset, and force arm reports to the
receiver. The bypass report includes the zone number, zone name, and the user number
of the individual bypassing the zone.
Code Change Reports
YES allows the panel to send all code additions, changes, and deletions to the receiver.
The code change report includes the user number added or deleted and the user
number of the individual making the change.
Send Stored Messages
If a panel loses communication with the receiver, it will store any messages that are not
able to be sent while communication was down. Selecting YES allows the panel to send
all stored messages to the receiver once communication is restored. The time at which
each message was generated is also sent. Default is
NO
.
If the panel is programmed to communicate to a second IP address (IP2), Send Stored
Messages must be enabled for the panel to send a special check-off message to IP2
once communication is restored to the primary IP address (IP1).
Ambush
YES allows an ambush report to be sent any time user code number one is entered at a
keypad.
Selecting NO disables the ambush report and allows user code number one to operate
the same as all other codes.
SYSTEM REPORTS
O/C RPTS
NO
YES
ABORT
NO
YES
RESTORAL:
YES
NO YES DISARM
BYPASS NO
YES
CODE CHG NO
YES
SEND STORED
MESSAGES?
NO
YES
AMBUSH
NO
YES