STEP 4: WIRE OPTIONAL INPUTS AND OUTPUTS
Onboard Inputs
Door Switch (DS)
This terminal is not typically used for elevator access�
Connect a door contact or door position switch to indicate the status
of the elevator, whether it is open or closed�
This terminal is a Normally Closed input�
Request to Exit (RX)
This terminal is not typically used for elevator access�
Connect a motion sensing device or a mechanical switch to provide
RX capability to the elevator controller� RX can be used to activate
the elevator relay� When activated the RX activates the elevator relay
based on the programmed time�
This terminal is a Normally Open input�
Custom Input (CI)
This input triggers a rule programmed in Virtual Keypad�
This terminal is a Normally Open input�
Ground (G)
This terminal is the ground for the inputs�
Onboard Outputs
Aux Output 1 & 2 (O1 & O2)
Attach the negative wire of the device here�
The relay contacts must be connected to devices located within
98�5 ft (30m) of the X1�